N-Tron® Series 300 TX/FX Models User Guide
2-13
Installation
Revised 2015-12-04
Optional
Mounting
Most N-Tron® series products are designed to be mounted on industry standard 35mm DIN-Rail. However, DIN-
Rail mounting may not be suitable for all applications. The Universal Rack Mount Kit (P/N: URMK), shown in the
figure below, may be used to mount the 316TX/317FX unit to standard 19” racks as an option.
Connections
Power
Connection
(Side
View)
1.
Unscrew & Remove the DC Voltage Input Plug from the side header.
2.
Install the DC Power Cables into the Plug(s) (observing polarity on unit).
3.
Plug the Voltage Input Plug(s) back into the side header.
4.
Tightening torque for the terminal block power plug is
0.22 Nm/0.162 Pound Foot
.
5.
All LED’s will flash ON momentarily.
6.
Verify the Power LED stays ON (GREEN).
Note:
Only one plug must be connected to power for minimal operation.
Either V1 or V2 can be
connected to power for minimal operation. For redundant power operation, V1 and V2 plugs must
be connected to separate DC Voltage sources. Use wire sizes of 16-28 gauge (0.08mm
2
-
1.31mm
2
). The power cord should be limited to less than 10 meters in order to ensure optimum
performance.
Recommended 24V DC Power Supplies, similar to:
100VAC/240VAC: N-Tron series NTPS-24-1.3, DC 24V/1.3A