10 - MENU ITEMS AND FUNCTION
SYSTEM CONFIGURATIONS
At the time of installation, the product must be configured according to the type of system by selecting the relative parameter in the
“SETTINGS” menu.
There are 5 possible configurations, described below:
Configuration
Description
1
Room temperature control via boiler's on-board probe or by enabling external thermostat FACTORY SETTING
2
Room temperature control via boiler's on-board probe or enabling external thermostat; DHW production for
storage cylinder or storage with thermostat (optional).
3
Room temperature control via boiler's on-board probe or enabling external thermostat; storage cylinder DHW
production with NTC probe (10 kΩ ß3435).
4
External Puffer controlled by thermostat.
5
External Puffer controlled by NTC probe (10 kΩ ß3435).
CONFIGURATION 1 (FACTORY SETTING)