RED EPIC OPERATION GUIDE
COPYRIGHT © 2013 RED.COM, INC
955-0002_v4.0, REV-C
|
181
For example, when GPI trigger is used for Record Start / Stop.
Start Record:
On Ground to 3.3 V transition
During Record: Hold at 3.3 V
Stop Record:
On 3.3 V to Ground transition
During Stop:
Hold at Ground
TRIGGER BUTTON CIRCUIT
NOTE:
A pre-fabricated SYNC interface cable is available from RED Digital Cinema.
P/N 790-0154 – Video Sync – Camera to 3 BNC – 3 ft. (1m)
White BNC:
Shutter Sync / GPI
Yellow BNC:
SMPTE Timecode
Green BNC:
RS170A Genlock