MAINTENANCE

D-1

VISUAL INSPECTION

Clean interior of machine with a low pressure air
stream.  Make a thorough inspection of all compo-
nents.  Look for signs of overheating, broken leads or
other obvious problems.  Many problems can be
uncovered with a good visual inspection.

ROUTINE MAINTENANCE

1. Every 6 months or so the machine should be

cleaned with a low pressure airstream. Keeping
the machine clean will result in cooler operation
and higher reliability. Be sure to clean these areas:

All printed circuit boards

Power switch

Main transformer

   Input rectifier 

   Auxiliary Transformer

   Reconnect Switch Area

2. Examine the sheet metal case for dents or breakage.

Repair the case as required. Keep the case in good con-
dition to insure that high voltage parts are protected and
correct spacings are maintained. All external sheet
metal screws must be in place to insure case strength
and electrical ground continuity.

PERIODIC MAINTENANCE

Overload Protection
The machine is electrically protected from producing
high output currents. Should the output current
exceed 430A, an electronic protection circuit will
reduce the current to approximately 100A. The
machine will continue to produce this low current until
the protection circuit is reset. Reset occurs when the
output load is removed.

Thermal Protection
Thermostats protect the machine from excessive
operating temperatures. Excessive temperatures may
be caused by a lack of cooling air or operating the
machine beyond the duty cycle and output rating. If
excessive operating temperature should occur, the
thermostat will prevent output voltage or current. The
meter will remain energized during this time. 

Thermostats are self-resetting once the machine cools
sufficiently. If the thermostat shutdown was caused by
excessive output or duty cycle and the fan is operating
normally, the Power Switch may be left on and the
reset should occur within a 15 minute period.

SAFETY PRECAUTIONS

ELECTRIC SHOCK can kill.

 Do not touch electrically live parts or

electrode with skin or wet clothing.

 Insulate yourself from work and

ground

 Always wear dry insulating gloves.

------------------------------------------------------------------------

EXPLODING PARTS can cause
injury.

Failed parts can explode or cause other
parts to explode when power is applied.

Always wear a face shield and long
sleeves when servicing.

------------------------------------------------------------------------

See additional warning information

throughout this operator

s manual and

the Engine manual as well.

-----------------------------------------------------------

WARNING

CAPACITOR DISCHARGE PROCEDURE
1. Obtain a power resistor (25 ohms, 25 watts).

2. Hold resistor body with electrically insulated glove.

DO NOT TOUCH TERMINALS. Connect the resis-
tor terminals across the two studs in the position
shown. Hold in each position for 1 second. Repeat
for all four capacitors. 

3. Use a DC voltmeter to check that voltage is not

present across the terminals on all four capacitors.

CAPACITOR
TERMINALS

RESISTOR

Содержание EX350i

Страница 1: ...fety in mind However your overall safety can be increased by proper installation and thoughtful operation on your part DO NOT INSTALL OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND T...

Страница 2: ...KER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy...

Страница 3: ...ctrical earth ground 3 f Maintain the electrode holder work clamp welding cable and welding machine in good safe operating condition Replace damaged insulation 3 g Never dip the electrode in water for...

Страница 4: ...prevent the welding sparks from starting a fire Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas Avoid welding near hydraul...

Страница 5: ...ns appropri s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise pa...

Страница 6: ...followed to avoid minor personal injury or damage to this equipment CAUTION Please Examine Carton and Equipment For Damage Immediately When this equipment is shipped title passes to the purchaser upon...

Страница 7: ...Cycle B 1 Operational Features and Controls B 1 Thru B 3 Remote Control of the Output Control and Weld Terminals B 3 Design Features and Advantages B 4 Auxiliary Power B 5 Limitations B 5 Recommended...

Страница 8: ...61 76m 200 250 FT 100 275 1 0 1 0 60 350 1 0 2 0 EX350i INPUT CURRENT Note 2 When operating on these inputs the line cord should be changed to an input conductor of 6 AWG or larger Recommended Fuse Si...

Страница 9: ...t ut y nibh euismod tincidun t ut laoreet dolore magna aliquam er laoreet dolore magna aliquam erat at Lorem ipsum dolor sit amet consect etuer adipisci ng Lorem ipsum dolor sit amet consect etuer ad...

Страница 10: ...ire feeder amphenol con nector on the rear of the EX350i Cobramatic Connection Instructions Turn the EX350i power switch off Connect the control cable from the Cobramatic to the 24 42 VAC 14 pin wire...

Страница 11: ...The arc control pots should be kept identical on the two machines QUICK DISCONNECT PLUGS A quick disconnect system is used for the welding cable connections The welding plug included with the machine...

Страница 12: ...t adjustment while in the hold period results in the prior to operation char acteristics stated above The displays blink indicat ing that the machine is in the Hold period 2 VOLT METER Prior to CV ope...

Страница 13: ...intended for most SMAW applications and Arc Gouging Arc Gouging Setting the output of the Stick Soft mode to 425 amps will enable the arc gouging mode The actual output current will depend on the size...

Страница 14: ...results in a crisp arc High pinch settings are preferable for welding FCAW and GMAW with CO2 CV FLUX CORED The CV FLUX CORED mode fea tures continuous control from 10 to 45 volts This mode was design...

Страница 15: ...6 will set the EX350i to mini mum output for the mode that has been selected while 10 volts supplied to 76 will set the EX350i to the maximum output for the mode Note In TIG mode 10 volts supplied to...

Страница 16: ...AC supply is rated at 5 5 amps and is protected by a 6 amp breaker located by the amphenol 24 VAC supply is rated at 5 5 amps and is protected by a 6 amp breaker located by the amphenol LIMITATIONS Th...

Страница 17: ...t Control K814 Arc Start Switch K812 Hand Operated Amptrol K870 Foot Operated Amptrol K930 1 TIG Module K428 K446 K449 LN 25 K617 1 or 2 K618 1 or 2 LN 742 K440 1 K567 1 LN 7 GMA K1559 1 K1564 1 LN 10...

Страница 18: ...Thermostats protect the machine from excessive operating temperatures Excessive temperatures may be caused by a lack of cooling air or operating the machine beyond the duty cycle and output rating If...

Страница 19: ...ed POSSIBLE CAUSE lists the obvious external possibilities that may contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possible Cause...

Страница 20: ...2 Welding procedure is drawing too much output current or duty cycle is too high Reduce output cur rent duty cycle or both 3 There is internal damage to the power source Contact an autho rized Lincoln...

Страница 21: ...ON Thermal symbol is lit Wire feeder won t work Apparently no power to wire feeder 1 Check for proper fan operation 2 Check for material blocking intake or exhaust louvers 1 Check circuit breakers by...

Страница 22: ...ver Check the machine Self clearing as current fault interrupt possibly ground condition ceases caused by noise or a signal level If problem persists misc hardware fault 1 contact an authorized Lincol...

Страница 23: ...ial three second period are displayed for 1 sec ond each Weld mode is changing A constant voltage weld mode is selected machine output is off The numeric value in the right display is the work point A...

Страница 24: ...A I G H T P L U G 1 4 P I N T O P O W E R S O U R C E C A B L E R E C E P T A C L E 6 S O C K E T C A B L E R E C E P T A C L E 1 4 S O C K E T T O 1 L N 7 W I R E F E E D E R S T O 1 K 8 5 7 R E M O...

Страница 25: ...TRIC SHOCK CAN KILL I N V E R T E C W I T H 1 1 5 V A C S 1 9 4 0 4 K867 PLUG TO LN 7 CONNECTION DIAGRAM N A W E L D I N G C A B L E M U S T B E S I Z E D F O R C U R R E N T A N D D U T Y C Y C L E O...

Страница 26: ...C A B L E E F D A B C 7 7 7 6 7 5 S P A R E 4 2 2 1 8 2 8 1 4 2 4 1 G N D 3 1 3 2 N D N D R E M O V E 6 P I N P L U G F R O M K 4 3 2 C A B L E I N O R D E R T O C O N N E C T K 8 6 7 P L U G L A B E...

Страница 27: ...5 A M P 1 1 5 V A C 2 A M P I N V E R T E C F R A M E C O N N E C T I O N N D N D F O R W I R E F E E D E R S T H A T R E T U R N A S I G N A L F O R W E L D I N G O U T P U T U S E I S O L A T I O N...

Страница 28: ...C Y C L E O F A P P L I C A T I O N N B D I A G R A M S H O W S E L E C T R O D E P O S I T I V E T O C H A N G E P O L A R I T Y T U R N P O W E R O F F R E V E R S E E L E C T R O D E A N D W O R K...

Страница 29: ...I T Y T U R N P O W E R O F F R E V E R S E E L E C T R O D E A N D W O R K C A B L E A T P O W E R S O U R C E E L E C T R O D E C A B L E T O L N 7 T O W O R K 1 4 P I N A M P H E N O L L N 7 C O N...

Страница 30: ...575V 550 460V 440 230V 220 380 415V 208V 200 7 2 3 8 9 4 6 1 5 10 11 12 13 14 15 16 609 602 612 607 901 90 3 804 903 7 2 3 8 9 4 6 1 10 5 2 2 3 4 1 5 7 8 9 10 2 3 1 6 5 4 7 8 802 806 801 Y YELLOW W WH...

Страница 31: ...EX350i 14 79 12 44 3 44 21 60 27 82 5 50 10 00 MOUNTING HOLE LOCATIONS M19527 13 1 0 1 4 20 NUT 4 PLACES NOTE MOUNTING SCREWS CA 8 00 N NOT PROTR UDE MORE THAN 0 5 INCHES INSIDE THE MACHINE 11 84 3 50...

Страница 32: ...EX350i NOTES...

Страница 33: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y...

Страница 34: ...e Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentaci...

Страница 35: ...and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com World s Leader in Welding and Cutting Pr...

Отзывы: