background image

Safety

1

BAL_K32_K42_Z_EN_2V5_BLA_121-006454230

9 / 46

DANGER

Danger to life due to electric current!

a) In case of contact with live parts, there is an immediate danger to life due to electric shock.

Damage to or removal of the insulation or individual components can be life-threatening.

ð

Before starting work on active parts of electrical systems and equipment, ensure that all poles are
voltage free and that this is maintained for the duration of the work.

ð

Keep moisture away from live parts. This can lead to a short circuit.

ð

Never bridge fuses or put them out of operation.

ð

Do not connect the power supply until all work has been completed.

ð

Have work on the electrical system performed by qualified personnel only.

DANGER

Danger to life due to non-functioning safety devices of the fire protection system!

a) If safety devices of the fire protection system do not function properly, there is a risk of serious

or fatal injuries.

ð

Never disconnect the fire protection system from the power supply overnight.

ð

Do not disassemble, put out of operation or manipulate safety devices.

ð

Do not remove safety instructions on the system.

ð

Never block, hold open or otherwise prevent fire doors from closing.

ð

Have inspection, service and maintenance of the fire protection system carried out in accordance
with locally applicable regulations or according to a maintenance contract.

ð

Have the fire protection system checked and maintained according to the state of the art.

1.4

State of technology

This system was developed using state of the art technology and officially recognized technical safety
regulations. The system, depending on its options and diameter, comply with the requirements of the
Machine Guidelines 2006/42/EG as well as EN 16005 and DIN 18650 (D).

Nevertheless, danger may arise if not used as intended.

IMPORTANT

Installation, commissioning, inspection, maintenance and repair work may only be conducted
by qualified, trained and authorized technicians.
After commissioning or repair work, fill in the check list and give it to the customer for safe
keeping.
We recommend obtaining a service agreement.

1.5

Personal protective equipment

Personal protective equipment is used to protect persons from adverse effects on health. Personnel
must wear personal protective equipment during the various work activities on and with the system.

Personal protective equipment is explained below:

Hearing protection is used to protect the hearing from noise. As a rule of
thumb, hearing protection is compulsory from when normal conversa-
tion with other people is no longer possible.

Содержание K 32 Z

Страница 1: ...record K 32 Z K 42 Z User manual Your global partner for entrance solutions www record group ...

Страница 2: ...Document identification Article nr 121 006454230 Version 2 5 Publication date 05 07 2022 Translation of the original manual Subject to technical modifications Copyright agtatec ag ...

Страница 3: ...ontrol unit 17 3 3 3 Emergency stop button 17 3 3 4 Information on motion detectors 18 3 3 5 Vertical safety sensors drum edge 18 3 3 6 Information on safety strips 18 4 Options 19 4 1 Electromagnetic turnstile lock 19 4 2 Turnstile bar bolt lock 19 4 3 Lock mechanism status indicator and door position indicator 19 4 4 BDE V key switch 20 4 5 Key pivot contact SSK 20 4 6 Disabled button 20 4 7 Sta...

Страница 4: ...n 29 6 7 Special function selection 30 6 8 Operating lock via the keyboard 30 7 Servicing and maintenance 31 7 1 General remarks 31 7 2 Monthly inspection work performed by the operator 31 7 3 Cleaning and care 33 8 Malfunctions 35 8 1 Conduct during malfunctions 35 8 1 1 Troubleshooting options 35 8 1 2 Tips for troubleshooting 35 8 1 3 Status display and troubleshooting BDE D KTA 36 8 1 4 Restar...

Страница 5: ... BAL_K32_K42_Z_EN_2V5_BLA_121 006454230 5 46 List of changes Change Location Complete revision of all Sections and content Entire document New Section structure Entire document Revision of all graphics Entire document ...

Страница 6: ...ad to severe injury or death DANGER Against an imminent or latent hazardous situation that could lead to electric shock and cause serious injury or death 1 2 Intended purpose of use The system is designed exclusively for use as a pedestrian passage The installation must only occur in dry areas If there are deviations then proper waterproofing and water drains will be required on site Any other app...

Страница 7: ...y overnight ð Settings should only be made by personnel qualified to do so ð Do not disassemble put out of operation or manipulate safety devices ð Have faults rectified by specialist personnel or by personnel qualified to do so ð Have service and maintenance carried out according to locally applicable regulations or accord ing to a maintenance contract CAUTION Risk of malfunctions material damage...

Страница 8: ...m when it is moving ð Do not open or remove protective covers during operation ð Do not permanently remove covers from the system ð Only carry out inspection service maintenance and cleaning when the system is stationary and switched off CAUTION Danger of material damage or injury due to non functioning safety devices a If safety devices are not functioning manipulated or put out of operation ther...

Страница 9: ...ors from closing ð Have inspection service and maintenance of the fire protection system carried out in accordance with locally applicable regulations or according to a maintenance contract ð Have the fire protection system checked and maintained according to the state of the art 1 4 State of technology This system was developed using state of the art technology and officially recognized technical...

Страница 10: ...protects personnel in busy work areas from collisions with vehicles Depending on the place of work and the working environment the protective equipment varies and must be adapted accordingly In addition to protective equipment for specific work the work site may require other protective equipment for example a harness In hygiene protected areas special or additional requirements of personal protec...

Страница 11: ... Carl Benz Str 5 15 D 77972 Mahlberg It is prohibited to reproduce distribute or use the manuals for purpose of competition without the writ ten authorization of BLASI GmbH Violation of the here stated copyrights will be prosecuted and fined with compensation of damage Subject can change without prior notice Differences between product and manual are thereby possible 2 3 Product identification The...

Страница 12: ...k Disassembly Assembly Commissioning Operation Audit Main tenance Troubleshooting Decommissioning The qualified personnel have several years of professional experience in the technical field e g as mechanics or machine fitters The qualified personnel are aware of the residual risks arising from the installation site and due to their professional training knowledge and experience are able to carry ...

Страница 13: ...sage height I Cladding height J Total height Q Total diameter T Exterior diameter U Interior diameter 3 1 1 Main mechanical components Abbreviation Description a Drum wall Curved fixed aluminum frame for supporting curved glass or panelling b Drum wall edge Fixed structure made of vertical frame profiling for accommodating control units c Rotation unit turnstile Rotating inner part of the door ...

Страница 14: ...elected with the corresponding BDE D KTA control unit A built in error analyzer detects operating errors Safety sensors prevent hazardous rotational movement which slows down or stops the turnstile at the right time The operating state or system error is displayed on the BDE D KTA control unit 3 3 Safety features and control elements K32 K42 Interior View in the closed position Operating element v...

Страница 15: ...stallation AKI AKA 2 Vertical forward sensor radial protective sliding wing OP VLS 3 3A 3B Vertical sensors drum edges OP VSS 4 Horizontal heel protection light barrier SLOW OP HSR 5 Horizontal heel protection light barrier STOP OP HSR 6 Vertical safety strips drum edges SL TRK 7 Vertical safety strip radial protective sliding wing SL RSF 8 Vertical safety strip radial fixed wing SL VSR 9 Vertical...

Страница 16: ... 31 Sliding door control unit BDE D STA 32 Traffic light red green alternatively in the standing column 33 Turn key switch night shield 34 Light barriers pivot wing joints 35 Emergency open button 36 Contact mat exit direction 37 Contact mat entrance direction 38 On site code card reader 1x interior and 1x exterior 39 Horizontal sensor strip opening and closing side 40 Lock mechanism status indica...

Страница 17: ... canopy panels made of bent aluminum sheets The entire drive system and controls are located behind the canopy panels The ceiling panels are part of the turnstile unit and are lined with concentric cut aluminum panels which can be removed for inspection 73 External control box 74 Deadman button 3 3 2 BDE D KTA control unit The electronic BDE D KTA control unit is a convenient input and output term...

Страница 18: ...hen a safety sensor is activated inside the danger zone the turnstile will either stop immediately or switch to slow speed depending on how the para meters have been set on the door control As long as a safety sensor is activated the stop setting will be held The slow speed setting remains active until the turnstile reaches the end position Then the turnstile will accelerate again and resume until...

Страница 19: ...e position from the outside of the door until you hear the locking pin en gage Ensure that the turnstile can no longer be rotated manually 4 2 Turnstile bar bolt lock The turnstile can be locked with a bar bolt lock integrated in the door frame profile By rotating the profile cylinder together with the ceiling construction and or additionally with a fitted socket integrated in the floor 4 3 Lock m...

Страница 20: ... control unit by turning the key switch to the left until it stops 4 5 Key pivot contact SSK When the key pivot contact is activated see Safety and operating components legend the turnstile starts and rotates a minimum of 360 in all operating modes except for MANUAL mode In the MANUAL mode or when the emergency stop switch is activated the turnstile can only be rotated manually with the exception ...

Страница 21: ...or is prevented for example by a defective sensor the turnstile can still be rotated to a desired position in both directions of rotation by an authorized person via the key emergency operation switch see Safety and operating components legend Function triggers a rotation at reduced speed Can ignore safety sensors The emergency stop button remains the overriding function Switch Operating mode Func...

Страница 22: ...e is activated Then the turnstile will stop When the electric safety strip is no longer activated and no safety sensors are activated the turnstile will start and accelerate to the preset walking speed 4 11 Air curtain control Direct ventilation to the interior via an air duct built into the doorway The air curtain is controlled by a potential free door contact that triggers once the turnstile sta...

Страница 23: ...figuration the lights can either be switched ON or OFF from an external spot or automatically depending on the operating mode selected via the door control Parameter setting Operating mode Lighting condition Inactive factory setting OFF or AUTOMATIC or CONTIUOUS or MANUAL Permanently OFF Only when the turnstile is turning AUTOMATIC or CONTIUOUS or ONE WAY ON Permanent LOCKED or AUTOMATIC or CON TI...

Страница 24: ...witch Opening process the night shield is opened by turning the key reversing switch to the right see arrow direction and holding the position If the night shield is locked electrically then it will simultaneously unlock The opening process will stop when the key reversing switch is no longer being turned or held The opening process will resume by turning the key to the right again and holding the...

Страница 25: ...automatically and remains open If switched to the LOCKED operating mode the night shield closes again automatically Security sensors if the detection area of the security sensors is entered during the closing process the night shield will open reverse immediately If no security sensors are activated the night shield will close and lock automatically Collision detection if the night shield wing str...

Страница 26: ...he power supply off completely via a main switch or residual current circuit breaker 5 4 Electrical specifications of the door control KST200 Type of control 1x KST200 Master 1x KST200 Slave 1x STM20 if with night shield 1x STM20 For K22 with sliding door Up to 6x AST200 Motor control Motor Switching power supply for control voltage 100 240 VAC 24 VDC 200 W short circuit proof Switching power supp...

Страница 27: ...Specifications 5 BAL_K32_K42_Z_EN_2V5_BLA_121 006454230 27 46 5 6 Sound pressure level The A weighted emission sound pressure level of the drive is less than 70 dB LpA_ 70dB A ...

Страница 28: ...see example 1 2 However the instructional symbol will be also be displayed Both instructional symbols could be displayed at the same time see example 3 Type Instructional symbol Information Error Example 1 Operating mode with information symbol Example 2 Operating mode with error symbol Example 3 Operating mode with both instructional symbols 6 3 Menu display You can switch to the menu display by ...

Страница 29: ...on operating mode display icon function Locked The turnstile rotates to the home position The turnstile locks automatically in the home position if a turnstile lock is available Automatic The turnstile and the rotation at walking speed are activ ated by the motion detectors If the motion detector is not activated again the turnstile rotates to the home position and stops press briefly Continuous r...

Страница 30: ... selection Select the special functions by pressing the respective button on the BDE D KTA control unit button operating mode display icon function press again One turn By pressing the key the turnstile unlocks if turnstile lock is present and starts a turning movement 360 In the home position the turnstile is locked again 6 8 Operating lock via the keyboard Locking the control unit Press key sequ...

Страница 31: ...rings sliding points and power transmission For documentation and information purposes the testing and servicing work as well as the condition of the system are recorded in a test log book The test log book must be kept for at least one year or until the next testing servicing IMPORTANT The testing and or servicing interval according to the manufacturer s specification is at least 1 to 2 times a y...

Страница 32: ... emergency stop button Reset the emergency stop button The turnstile must stop immedi ately After resetting the turnstile will start again 25 Function test disabled button Start the turnstile rotating in AUTOMATIC or ONEWAY mode The turnstile rotates at slow speed in the CONTIUOUS operating mode Press the disabled button Perform this test from the interior and the exterior of the door The turnstil...

Страница 33: ...s a Risk of burning hands when replacing components ð Allow components to cool for at least 5 minutes before replacement and wear safety gloves if ne cessary Visual inspection of the lighting Check that the lamp is firmly seated and switch on the lighting Lamps must be correctly mounted and functioning WARNING Resetting the folding turnstile wings a Squeezing and retracting the fingers by movement...

Страница 34: ...d inside the plant must be avoided c It is recommended to impregnate the safety strips and sensors with a water repellent care product IMPORTANT Any other cleaning agents not mentioned above must not be used What Interval Cleaning agent General parts Weekly Damp cloth neutral to slightly al kaline aqueous wetting agent solu tion vinegar diluted with water Sensors safety strips Weekly Plastics clea...

Страница 35: ... service centre Malfunctions Causes Solutions Turnstile is blocked can not be elec trically unlocked Lock does not open Lock is jammed in the lock latch Lock is defective Switch to MANUAL operating mode and shake turnstile briefly Turnstile rotates permanently but very slow Disabled button is defective Safety sensors on the top of the turnstile wing is activated or de fective Check the disabled bu...

Страница 36: ...cking the door Reset button snap in Perform reset If not successful contact service Emergency stop TA NHTI 101 Outside emergency stop TA NHTA actu ated EmergencyStop Immediate stop of the rota tion Unlocking the door Reset button snap in Perform reset If not successful contact service Emergency stop TA NHTA 102 Radar inside AKI Door rotates permanently in the operating modes AUTO MATIC and ONE WAY...

Страница 37: ...func tion set Stop rotation or re duce rotation speed Remove object from the detection range of the sensor Check sensor for contamination clean if possible Perform reset If not successful contact service VSR1 active 112 Vertical sensor rotor blade 2 OP VSR2 OptoStop OptoSlow de pending on the sensor func tion set Stop rotation or re duce rotation speed Remove object from the detection range of the...

Страница 38: ... contact service SL VSR2 active 121 Horizontal safety bar ro tor blad 3 SL FES3 SafetyStop Immediate stop of the rotation Remove object from safety edge possibly dirt on the floor under a heel guard Perform reset If not successful contact service SL FES3 active 122 Vertical safety bar rotor blade 3 SL VSR3 SafetyStop Immediate stop of the rotation Remove object from safety edge possibly dirt on th...

Страница 39: ...e turnstile wing released Immediate stop of the rota tion Release of the escape route via HST200 See triggering states Reset the turnstile wings Perform reset If not successful contact service Breakout wing enabled 133 Flow sensor rotor blade 1 OP VLS1 OptoStop OptoSlow de pending on the sensor func tion set Stop rotation or re duce rotation speed Remove object from the detection range of the sens...

Страница 40: ...t service Sliding door open 144 Test error vertical sensor stator inside OP VSSI ErrorStop Immediate stop of the rotation Perform reset If not successful contact service OP VSSI test error 145 Test error vertical sensor external stator OP VSSA ErrorStop Immediate stop of the rotation Perform reset If not successful contact service OP VSSA test error 146 Test error vertical sensor rotor blade 1 OP ...

Страница 41: ...erform reset If not successful contact service OP HSR2 active 156 Stormlock AuxIn Immediate stop of the rota tion Release of the Stormlock in terlocks Check reset switch Perform reset If not successful contact service AUX IN Stormlock act ive 157 Emergency open AuxIn Immediate stop of the rota tion Release of the escape route via HST200 Check reset switch Perform reset If not successful contact se...

Страница 42: ...Horizontal safety bar ro tor blade backwards 1 SL FES1 2 SafetyStop Immediate stop of the rotation Remove object from safety edge possibly dirt on the floor under a heel guard Perform reset If not successful contact service SL FES12 active 167 Vertical safety bar rotor blade backwards 1 SL VSR1 2 SafetyStop Immediate stop of the rotation Remove object from safety edge possibly dirt on the floor un...

Страница 43: ...ries due to dangerous movements in the event of malfunctions or failure of safety devices are possible ð Make sure that nobody obstructs the turnstile and that no person approaches the system that could cause the turnstile to rotate Procedure Press key BDE D KTA display Function Keep the key pressed until the display appears E Depending on the mode se lected Press the key briefly if no restart No ...

Страница 44: ... is stopped immediately and the turnstile is then freely ro tatable The key emergency operation button or start button are without function NOTICE An emergency operation is only possible for a certain bridge period with an external on site or integrated UPS Uninterruptible Power Supply If the system is equipped with a bistable electric turnstile lock the turnstile remains locked in the basic posit...

Страница 45: ...etely disassembled in reverse order The automatic door mainly consists of the following materials Aluminum Linking profiles Gearbox Drive panel Door wing profiles and side profiles Various profiles and small parts Steel iron parts Stainless steel casing Floor panel Box recess for floor installation Optional spacer or reinforcement profiles Gear components springs Various small parts like fittings ...

Страница 46: ...Your global partner for entrance solutions ...

Отзывы: