Malfunctions
8
BAL_K32_K42_Z_EN_2V5_BLA_121-006454230
39 / 46
127
Night shutter not open
or drum wall breakout
not closed (UW-
POS2_S)
– Immediate stop of the rota-
tion
– Fully open the night shield
– Close / reset drum wall breakout com-
pletely
– Reset pivot wings
– Perform reset
UW-POS2 stator active
128
Pendulum wing 1 de-
flected (UW-POS1_R)
– Immediate stop of the rota-
tion
– Fully open the night shield
– Close / reset drum wall breakout com-
pletely
– Reset pivot wings
– Perform reset
UW-POS1 rotor active
129
Pendulum wing 2 de-
flected (UW-POS2_R)
– Immediate stop of the rota-
tion
– Fully open the night shield
– Close / reset drum wall breakout com-
pletely
– Reset pivot wings
– Perform reset
UW-POS2 rotor active
130
Commissioning required – Immediate stop of the rota-
tion
– Perform reset
– If not successful, contact service
Learning cycle required
131
Self-test is executed
– Stop the rotation
– Wait until self-test is finished (approx. 5
sec.)
– Perform reset
– If not successful, contact service
Self-test active
132
Escape route, turnstile
wing released
– Immediate stop of the rota-
tion
– Release of the escape route
via HST200
– See triggering states
– Reset the turnstile wings
– Perform reset
– If not successful, contact service
Breakout wing enabled
133
Flow sensor rotor blade
1 (OP-VLS1)
– OptoStop, OptoSlow, de-
pending on the sensor func-
tion set Stop rotation or re-
duce rotation speed
– Remove object from the detection range
of the sensor
– Check sensor for contamination, clean if
possible
– Perform reset
– If not successful, contact service
OP-VLS1 active
134
Flow sensor rotor blade
2 (OP-VLS2)
– OptoStop, OptoSlow, de-
pending on the sensor func-
tion set Stop rotation or re-
duce rotation speed
– Remove object from the detection range
of the sensor
– Check sensor for contamination, clean if
possible
– Perform reset
– If not successful, contact service
OP-VLS2 active
135
Start button 1 Rotor
(TA-SRT1_R)
– Door rotates permanently
– Check push button
– Perform reset
TA-SRT1 rotor active
136
Start button 2 Rotor
(TA-SRT2_R)
– Door rotates permanently
– Check push button
– Perform reset
TA-SRT2 rotor active
137
Internal stator safety bar
2 (SL-SI2)
– SafetyStop, Immediate stop
of the rotation
– Perform reset
– If not successful, contact service
SL-SI2 active