Description
3
BAL_C127-SU_OFFSET_EN_1V0_REC_121-006454770
15 / 32
3.5
Accessories
3.5.1
Lever arm
– For direct connection and force transmission between the output shaft and door leaf.
– The lever arm can be installed in the door panel or bottom rail profile of the door leaf.
– A suitable counteracting bearing must be provided for the door leaf.
NOTICE
The lever arm is manufactured according to customer requirements.
3.5.2
Gearbox cover with position switch
Gearbox cover with position switch
MS gearbox cover with switch
(position switch)
Art. 102-127808257
The normal gearbox cover is replaced by the gearbox cover with position switch. The adjustable
switch clasp in the gearbox housing actuates the microswitch with floating contact.
Solutions with externally mounted microswitches and appropriate operation or magnetic contacts
need to be implemented by the customer onsite.
Information for installing and setting can be found in the attached instructions
Retrofitting mi-
croswitches
(Nr. 102-127109418).
CAUTION
Unforeseen adjustment of the switch clasp during operation
a) Incorrect information about the position of the door leaf
ð
The switch contact may not be used for safety applications.
NOTICE
The AUX1_OUT output can be programmed with the functions Closed or Locked:
Closed: Door is closed.
Locked: Door is closed and locked.
For parameter configuration please also see the chapter
Parameter Descriptions
!