background image

EC Declaration of Conformity

 

 

Issuer's name and address:

REC SOLAR PTE. LTD. 

20 Tuas South Avenue 14 

SINGAPORE 637312 

SINGAPORE

 

Product: 

Crystalline silicon terrestrial photovoltaic modules 

Type designation:

RECxxxPE

*

  

REC Peak Energy

*

 Series; 

RECxxxPE 72  

REC Peak Energy 72

*

 Series; 

RECxxxPE Z-Link 

REC Peak Energy Z-Link Series; 

RECxxxPE Z-Link-S 

REC Peak Energy Z-Link-S Series; 

RECxxxPE2SM 50

*

 

REC Peak Energy 2S Mono 50

*

 Series; 

RECxxxTP

*

 

REC TwinPeak

*

 Series; 

RECxxxTP 72

*

 

REC TwinPeak 72

*

 Series; 

RECxxxTP2

*

 

REC TwinPeak 2

*

 Series; 

RECxxxTP2S 72

*

  

REC TwinPeak 2S 72

*

 Series; 

RECxxxNP

*

 

REC N-Peak

*

 Series; 

RECxxxAA

*

 

REC Alpha

*

 Series; 

 

*

indicates type/name can include any of the suffixes: ECO, BLK, BLK2, Black, XV, Mono (M in product code), e.g., RECxxxTP2SM 72 XV; REC TwinPeak 2S Mono 72 XV.

 

The object of the declaration described above is in conformity with the relevant Union harmonisation legislation:

 

 

2014/35/EU

 

"Directive of the European Parliament and of the Council on the harmonisation of the laws of the Member States relating 

to the making available on the market of electrical equipment designed for use within certain voltage limits".

 

 

The technical documentation and full compliance with the standards listed below proves the conformity of the product with the

requirements of the above-mentioned EC Directive and its conformity with the safety requirements of the EC Low-Voltage Directive 

2014/35/EU.:

 

DIN EN 61215 (VDE 0126-31):2006-02; EN 61215:2005

DIN EN 61730-1 (VDE 0126 Teil 30-1):2007-10; EN 61730-1:2007-05

DIN EN 61730-1/A1 (VDE 0126-30-1/A1):2012-09; EN 61730-1:2007/A1:2012

DIN EN 61730-1/A2 (VDE 0126-30-1/A2):2014-01; EN 61730-1:2007/A2:2013

DIN EN 61730-1/A11 (VDE 0126-30-1/A11):2015-08; EN 61730-1:2007/A11:2014

DIN EN 61730-2 (VDE 0126-30-2):2012-09; EN 61730-2:2007 + A1:2012

IEC 61215-1:2016; EN 61215-1:2016

IEC 61215-1-1:2016; EN 61215-1-1:2016

IEC 61215-2:2016; EN 61215-2:2017

IEC 61215:2005

IEC 61730-1:2004

IEC 61730-1:2004/AMD1:2011

IEC 61730-1:2004/AMD2:2013

IEC 61730-1:2016

IEC 61730-2:2004

IEC 61730-2:2004/AMD1:2011

IEC 61730-2:2016

Remark: The VDE Testing and Certification Institute, Merianstr. 28, 63069 Offenbach (Germany), has tested and certified the 

product(s) according to these standards.

 

Certificate No. 

40046983

 

File Reference 

5017538-3972-0001 / 253159

 

 

This declaration is issued under the sole responsibility of the manufacturer and loses its validity if the product is misused or modified 

without proper authorization from REC.

Ter Soon Kim

 – Chief Operating Officer 

Singapore, April 3, 2019

 

www.recgroup.com

16

REC Installation Manual - REC Alpha 72 Series  - IEC 61215 /61730
Rev A - 02.20 

Ref: NE-06-23

EC DECLARATION OF CONFORMITY

Содержание Alpha 72 Series

Страница 1: ...rec Alph 72 SERIES INSTALLATION MANUAL FOR ALL REC ALPHA 72 SOLAR PANELS CERTIFIED ACCORDINGTO IEC 61215 IEC 61730 STANDARDS...

Страница 2: ...AGEMENT 11 PANEL MAINTENANCE 12 RECYCLING 12 DISPOSAL OF OLD ELECTRICAL AND ELECTRONIC EQUIPMENT 12 PANEL CHARACTERISTICS 13 Technical Properties REC Alpha 72 Series 13 ANNEX 1 INSTALLATIONS ON WATER...

Страница 3: ...ore installers are responsible for the following Only qualified personnel must perform work on photovoltaic systems such as installation commissioning maintenance and repairs Be sure to follow the saf...

Страница 4: ...erved during handling to avoid the risk of sparking fire hazards burns and lethal electric shocks Exercise extreme caution when wiring panels and look out for damaged or dirty cables etc Never insert...

Страница 5: ...voiddamageordegradationtothepackagingorpanelcomponents pallets and panels must be stored in a controlled environment ideally internal where it is protected from the elements e g rain dust and direct s...

Страница 6: ...bundled together so loops are as small as possible String configurations must be checked before commissioning If open circuit voltage Voc and short circuit current Isc deviate from specification this...

Страница 7: ...mp grip length and the central point of the fixation e g the bolt is fully within the required clamping zone as indicated on the following pages CLAMP SPECIFICATIONS Clamp installation must be carried...

Страница 8: ...g 3 Clamping zones for panels with rails parallel to short side CAUTION The minimum grip length of each clamp and its center point must be fully located in the same color zone to be rated to that load...

Страница 9: ...eledgeofeachpanelmustbesupportedbytworails figs 2a 2b ofaluminiumorgalvanized steelsuitablefortheapplicationandappropriateforthelocalenvironment Observethefollowingprocedureswhenusingmountingholes The...

Страница 10: ...hown in fig 9 and can be further identified by the grounding symbol stamped in the frame next to it Check all applicable requirements before beginning installation Suitable grounding clips lugs or oth...

Страница 11: ...standards e g IEC 62852 or UL 6703 to ensure they are fit for purpose and safety Useofanychemicalsorlubricantsontheconnectorsorcontactsmayonlybecarriedoutinlinewiththeconnectormanufacturer sinstructio...

Страница 12: ...local guidelines and regulations By ensuring REC solar panels are disposed of correctly you will help prevent potential negative impact on the environment and human health The majority of the panel c...

Страница 13: ...ewithIEC62790 Connectors St ubliMC4Evo2 PV KBT4 EVO 2 PV KST4 EVO 2 4mm inaccordancewithIEC62852 IP68onlywhenconnected Cable 4 mm solar cable 1 2 m 1 3 m in accordance with EN 50618 Dimensions 2063 x...

Страница 14: ...installation must have sufficient length and slack to prevent damage due to water level changes and wave motions ii Mounting panels Installation of REC solar panels must be in accordance with the afor...

Страница 15: ...r instructions to ensure optimum mounting of MLPE device and prevent any slippage during operation MLPE devices may also be attached to the mounting construction In such cases refer to the instruction...

Страница 16: ...nformity of the product with the requirements of the above mentioned EC Directive and its conformity with the safety requirements of the EC Low Voltage Directive 2014 35 EU DIN EN 61215 VDE 0126 31 20...

Страница 17: ...RECInstallationManual RECAlpha72Series IEC61215 61730 Rev A 02 20 Ref NE 06 23 17 DOCUMENTHISTORY Date Revision Reason 02 2020 A First release...

Страница 18: ...RECSOLARPTE LTD 20TUASSOUTHAVENUE14 SINGAPORE637312 SINGAPORE Tel 6564959228 Mail post recgroup com www recgroup com 18 RECInstallationManual RECAlpha72Series IEC61215 61730 Rev A 02 20 Ref NE 06 23...

Отзывы: