PYROTECH INBUILT MODEL
•
Unit installed into an existing “working” fireplace requires an AGA approved 150mm gas cowl.
If the chimney does not draw properly, a 900mm length of flexi flue (supplied with unit) should
be fixed to the flue spigot on top of the heater. The flexi flue should be fixed in the vertical
position in a manner that does not allow the flue to fall or come away from the spigot.
•
If the fireplace is not a working fireplace, then an approved 100mm flue system with 100mm
AGA approved gas cowl should be used. (Optional extra)
•
If the flue is exposed or enclosed with combustible materials, an approved 100/150mm twin
skin flue is required. (Optional extra)
Pyrotech Inbuilt Installation Procedure
Check chimney for correct venting of fumes
Position unit centrally.
Connect to gas supply using 15mm copper union.
Connect to power supply.
Remove glass and assemble log or pebble set as shown (Figures 1 - 12).
TICK BOXES
Figure (1) Remove decorative fasteners from
four corners of shield glass panel.
Figure (2) Remove shield glass panel.
572mm
Gas Pipe
(Alternatives)
Electrical Cord
360mm
865mm
635mm
280mm
600mm
170mm
45mm
30mm
40mm
45mm
240mm
Trim
680mm
370mm
6