Operating instructions
Peristaltic Pump IP Series
18
7 Mount the front cover.
8 Turn the rotor with the help of the motor so that the
remaining roller presses against the pump hose.
9 Dismount the front cover.
10 Re-attach the second roller with shims back onto the rotor.
11 Lubricate the pump hose and the rollers.
12 Attach the front cover to the pump housing.
13 Mount the pipes from both discharge and suction sides.
14 Open all of the valves.
7.2.2.2 Model IP-60
1 Clean the interior surfaces of the pump casing.
2 Lubricate the internal surfaces of the pump casing at the
contact surfaces to the pump hose with original silicon
grease.
3 Check the rollers. Ensure that the roller surfaces are not
damaged.
4 Lay the pump hose into the pump casing.
5 Attach the inserts at both hose ends with the help of the
press flange.
6 Fasten the two parts of press flanges us the base.
7 Fasten the press flange to the pump casing.
8 Fasten the connections to the press flange.
9 Mount the front cover.
10 Turn the rotor with the help of the motor so that the
remaining roller presses against the pump hose.
11 Dismount the front cover.
12 Re-attach the second roller with shims back onto the rotor.
13 Lubricate the pump hose and the rollers.
14 Attach the front cover to the pump casing.
15 Mount the pipes from both discharge and suction sides.
16 Open all of the valves.