Operating instructions
Peristaltic Pump IP Series
10
5.2.2 Discharge side
The discharge line is to be kept as straight and short as possible, in or-
der to avoid performance reduction. The diameter must correspond to
the rated diameter of the pump hose. A larger diameter is recommend-
ed in the event of viscose liquids. It is recommended to use a flexible
transition between two fixed pipes and the hydraulic connection of the
pump, in order to avoid the transmission of vibrations.
5.3
Adjusting the roller pressure
The peristaltic pump is equipped with shims, in order to adjust the pre-
cise pressure distance to the roller (dependent on speed and operating
pressure).
Fig 2:
1- Roller / 2- Shims