Operating instructions
Peristaltic Pump IP Series
16
7.2.1.2 Model IP-60
1 Close off all valves, in order to prevent leakage of the feed
chemical.
2 Dismantle the pipes from both discharge and suction sides
3 Remove the front cover.
4 Remove a roller (the roller that is not touching the pump
hose).
5 Mount the front cover.
6 Turn the rotor with the help of the motor so that the
remaining roller is not pressing against the pump hose.
7 Dismount the front cover.
8 Remove the connections.
9 Remove the press flange from the pump casing.
10 Remove the pump hose to be exchanged.
11 Dismantle the inserts from both pump hose ends.
7.2.2
Exchanging the pump hoses- installation
7.2.2.1 Models IP-30, IP-40, IP-50, IP-70 and IP-70D
1 Clean the interior surfaces of the pump housing.
2 Lubricate the internal surfaces of the pump housing at the
contact surfaces to the pump hose with original silicon
grease.
3 Check the rollers. Ensure that the roller surfaces are not
damaged.
4 Lay the pump hose into the pump housing.
5 Lay the press rings. Between the end of the hose and the
press ring, it has to be a distance of 3-7 mm.