background image

1. Clues for users

- Before putting the amplifier to the 230V currency, please read the following instruction.
- Doing any unknown service to the device by any unauthorized persons makes the depriving of guarantee 
  and can be the cause of  the worsening of technical parameters  and the safety of using.
- ATTENTION! The device must be supplied from the plug-in socket with the safety circuit connected ( 
  socket with grounding wheel).
- In case of changing the plug-in fuse, the plug  must be pulled off.
- The producer can introduce some changing to the device in case of modernizations or technical 
  progress, without the necessity to put them into the instruction as far as the basic parameters, that are 
  included in this instruction, are not changed.
The accessories of the amplifier:
- service manual with the guarantee card,
- spare fuse,
- plug-in cable,
- application software CD,

2. Using and general notices.

The modern amplifiers AMC- DSP4 (Powermixer) are designed to be used in sacral buildings, large, closed areas, 
conference rooms, where the high quality and the hearing of speaking is required. They

 are cooperating with the 

50V, 70V and 100V loud speakers line and with the loud speakers set of altogether impedance > = 4 Ù.

The amplifier has got: 8 symmetrical microphone  line channels to put in  the dynamic, capacitive and wireless 
microphones or the device with line level output and music channel to put in the record player, tuner or CD player 
(LINE  asymmetrical). To record, there is a separate RCA (RECORD) socket.
AMWL-DSP is a modern amplifier equipped in signaling DSP processor that enables precise correction of sound 
characteristics in buildings with very difficult acoustic conditions. The amplifier activates only those microphones, 
that are used in that moment, what eliminates sound surrounding influence coming from not used microphone 
channels. Each 1-8 channel is equipped in symmetrical XLR input, sensitivity regulation, Phantom power.plugged 
in, microphone/line switch, 100Hz high  pass filter, preamplification regulation, and timbre regulation 
(bas/soprano) designed in front of the case. In 1-8 channels, diodes signal the channel activity and the microphone 
transposition. 

3.  

Arrangement of elements and sockets. 

The view of the front board of the AMWL-DSP amplifier.

3

7

8

9

L I N E  C D

HIGH

HIGH

LOW

LOW

HIGH

HIGH

LOW

RECORD

EXIT

+

+

-

-

MIC.

MIC.

EAK

PEAK

PEAK

6

6

10

10

0

0

2

2

4

4

8

8

MASTER

0

0

0

0

0

0

2

2

2

2

2

2

4

4

4

4

4

4

6

6

6

6

6

6

10

10

10

10

10

10

8

8

8

8

8

8

 SPK-ZONE-LEVEL

6

6

10

10

0

0

2

2

4

4

8

8

E L E K T R O A K U S T Y K A

E L E K T R O A K U S T Y K A

ON

OFF

POWER

SETTINGS

ENTER

DIGITAL SIGNAL PROCESSOR

1 2 3

4

5

6

7

8

9

10

11

13

14

15

12

16

PRESET 1

PRESET 2

Содержание AMWL-9DSP4/400

Страница 1: ...d w ul 1M a j a 1 9 6 t e l 03 2 47 5 1 8 0 3 d o 5 www rduch com pl www naglosnienia com pl www naglosnienia eu e mail biuro naglosnienia com pl E L E K T R O A K U S T Y K A E L E K T R O A K U S T...

Страница 2: ......

Страница 3: ...ical microphone line channels to put in the dynamic capacitive and wireless microphones or the device with line level output and music channel to put in the record player tuner or CD player LINE asymm...

Страница 4: ...connect switch 30 XLR socket in particular channels 1 8 31 the particular outputs sensitivity regulation 32 3 positioned switch 1 Phantom power on off 2 MIC LINE switch 3 100 Hz high pass filter on of...

Страница 5: ...t press handwheel 8 ENTER To come back to the previous part press EXIT 9 5 clock adjusted preset number preset name IN2 IN1 NG LIM1 EQIN CR LIM2 Noise gate c d Preset name 0dB 0dB dB Threshold 90 dB N...

Страница 6: ...ment of particular inputs Output equalizer part EQ1 EQ2 EQ3 EQ4 filter type choice PeakingEQ LoSh6 LoSh12 HiSh6 HiSh12 frequency settings 20Hz 21 2kHz choice of one from five equalizer points Gain adj...

Страница 7: ...te part General options part servicing mode only for servicemen Passwords part adjustments of the possibility of displaying the control indicator vertical or horizontal choice of displaying graphs mod...

Страница 8: ...ssary Installation fileison CD added Dotnetfx35 exe platformcan be downloaded from the Microsoft II InthecatalogueVCMDriveryoucanfinddriversforusetheUSBportfromtheamplifierAMWL DSP4 CDM2 04 16 exe als...

Страница 9: ...regulation 20Hz 21 2kHz settings part place to open Settings panel part Equalizer input To record the project to the file the option Record the project Ctrl S in menu file should be chosen gain atten...

Страница 10: ...er part frequency regulation 20Hz 21 2kHz gain attenuation regulation 12dB 12dB filter width setting 0 05oct 3oct filter type choice PeakingEQ LoSh6 LoSh12 HiSh6 HiSh12 menu Options language language...

Страница 11: ...utput the eliminator is to be turn on eliminator s decoupling method choice frequency choice for phase shifter method Subwoofer part the Subwoofer works after pressing the switch ON Subwoofer option i...

Страница 12: ...JECT Ctrl S SAVE AS PRINT Ctrl P CLOSE EXIT Alt F4 CONNECT Ctrl Shift C DISCONNECT SAVE THE SETTINGS LANGUAGE PRESETS DATE BOARD CASCADE PROJECT S NAME ABOUT THE PROGRAM ENGLISH POLISH PRESET S NAME P...

Страница 13: ...omatic Bottom position ON PRE GATE signals are assigned before automatic Switch 2 AUTO MANUAL upper position AUTO mixer auto work function bottom position MANUAL standard mixer work Switch 3 ATTENUATI...

Страница 14: ...L 9DSP 400 100 AMWL DSP4 amplifiers have an additional 100W power terminal option where the delaycanbeset 100 W terminal can be switched on output DSP OUT 2 28 DSP OUT 3 27 or DSP OUT 4 19 It is the s...

Страница 15: ...erating with Phantom power recommended 1 chassis ground hot ve cold ve chassing grounding chassis grounding chassis grounding signal input terminal ring sleeve symmetrical terminal ring Asymmetric out...

Страница 16: ...antom Phantom Phantom HPF HPF HPF HPF HPF HPF HPF HPF 100Hz 100Hz 100Hz 100Hz 100Hz 100Hz 100Hz 100Hz 100Hz 100Hz 100Hz 100Hz 100Hz 100Hz 100Hz 100Hz 230V 50Hz DSP OUT 2 DSP OUT 3 GND LIFT GND LIFT GN...

Страница 17: ...phase shift measurements width height depth mm 443 x 135 x 340 5 point parametric equalizer delay line 0 85 m frequency band work temperature weight kg Limiter double peak on DSP input and on power en...

Страница 18: ...IE OTWIERA UWAGA WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE WARNING OF DANGEROUS ELECTRICAL VONTAGE IN THE HOUSING ARE NOT PROTECTET ELECTRON...

Страница 19: ...ower Fuse Ground measurements of the device according to VDE 0701 norm Other connections and connectors control Optical control of the whole Notices Signature Output power P U Z 200W 100V 50 400W 100V...

Страница 20: ...ment for a complaint is to provide the device in the original packing with the guarantee card to the place where the device was bought 5 In case of the damage of the device during the warranty period...

Отзывы: