Tank filling (Manual)
1 Select the "INFO" screen and press to access the TANK FILL screen (fig. 14).
The screen will display,
"
MAX
"
- the full tank volume
"
NOW
"
- the volume remaining in the tank
"
TO ADD
"
- volume to replenish
NOTE:
If more than one tank is enabled, there is a separate screen page for each tank (as
for the MAIN screen). Press the INFO menu key repeatedly to cycle between each
page.
2 Fill the tank to the desired level.
3 Confirm that "
MAX
" corresponds to the quantity in the tank. Adjust as necessary.
NOTE:
Move the screen cursor using the arrow keys and enter values via the numeric
keypad.
4 Press to reset to the full tank volume.
5 Confirm the alarm volume ( ) is OK (typically the volume needed to spray a
single bout). Adjust as necessary.
2.7.2
Tank filling (Automatic)
A Tank Inflow Sensor must be installed to measure the inflow. A Shutoff Valve must
be installed to stop the filling automatically.
1 Connect the inflow hose.
2 Select the "TANK FILL" screen as above.
3 Confirm that "
MAX
" corresponds to the quantity you want in the tank after filling.
Adjust as necessary.
4 Confirm that the "
NOW
" volume is the volume currently in the tank. Adjust as
necessary.
5 Confirm the alarm volume as above.
6 Press the key.
6
Figure 14
Resetting the Tank Volume