LIFTLOG 1000 – INSTALLATION AND CALIBRATION
33
“Correct from Weight” -
“Wf” on graph.
“Correct to Weight” -
“Wt” on graph.
The range over which the correction factor is applied.
“% Correction” -
Correction applied between 'Wf' and 'Wt' on
graph.
3.4.4 Sensor Setup
Press to edit settings requiring a numeric entry.
“
Reference Sensor
”
If fitted, the reference sensor only enables the weigh
button to operate at the weighing position.
“
Drop Sample Time
” The time after pressing the weigh button and the
“Sample Start Delay”, during which the weight is
sampled and averaged.
“
Sample Start Delay
” The time after pressing the weigh button, before the
solenoid activates and weight sampling commences.
This allows the hydraulic pressure to stabilize prior to
the sampling period and improves accuracy.
“
Overload Log Delay
” The time that the pressure is detected to be constantly over the “Overload Level” before logging an
overload event.
“
Overload Smoothing
” This helps to prevent unnecessary overload events being logged due to inadvertent pressure transients,
caused for example by sudden lifting or other movement.