LIFTLOG 1000 – INSTALLATION AND CALIBRATION
20
2.4.4 Electrical Connections
Route sensor leads inside conduit back to the junction box. Cable-tie the conduit securely to existing hydraulic lines or conduits.
Connect the wires according to the label on the junction box lid :
Input / Output
Wire
Colour
Terminator Connection
Pressure Sensor (on
Drop valve)
Blue
10
"P1"
Brown
4
"P1 +V"
Drop Valve Solenoid
Blue
16
“DROP VALVE 0V”
Brown
6
“DROP VALVE + (BROWN)”
Reference Sensor
Blue
13
"0V"
Brown
20
"REF SENSOR (BROWN)"
Remote Enter
Switch
Blue
14
"REMOTE ENTER 0V (BLUE)"
Brown
9
"REMOTE ENTER SIG (BROWN)"
Remote Weigh
Button
Blue
15
“WEIGH BUTTON 0V (BLUE)”
Brown
18
“REMOTE WEIGH BUTTON (BROWN)”
External Alarm
Blue
13
“0V”
Brown
5
“EXTERNAL ALARM +VE (BROWN)”
Power Supply
Blue
12
“POWER IN 0V (BLUE)”
Brown
1
“POWER IN +V (BROWN)”