METER MODE 

(cont.)

 

Each press of the GREEN button will increment the value above the cursor. Each press 

 

of the RED button for less than 3 seconds will move the cursor one place through the 

 

programmable setting of the displayed parameter. To store the new value press the RED 

 

button for greater than 3 seconds, then on releasing the RED button the next parameter 

 

for programming will be displayed. If no buttons are pressed within 10 seconds the 

 

display will revert to its normal operation mode without saving the new value.

 

Example:

 To change the value on Rate 1 Unit Cost the sequence of events will be as follows:

STEP    ACTION                                                                                DISPLAY                      

Remove COMMAND card.

Insert a valued COMMAND Card.

Press and release the RED button for less than 3 
seconds.

Press and hold the RED button for greater than 3 
seconds to store the value.

Press and hold the RED button for greater than 3 
seconds to store the value.

Press and hold the RED button for greater than 3 
seconds to store the value.

Press and hold the RED button for greater than 3 
seconds to store the value.

Press and hold the RED button for greater than 3 
seconds to store the value.

Press and release the GREEN button until the correct 
value is shown.

Press and release the RED button for less than 3 

seconds to move the cursor one place through the 

programmable setting of the displayed parameter.

Press and hold the RED button for greater than 3 
seconds to store the settings.

Press and hold the RED button for greater than 3 
seconds to store the settings.

Press and hold the RED button for greater than 3 
seconds to store the settings.

Press and hold the RED button for greater than 3 
seconds to store the settings.

Press and hold the RED button for greater than 3 
seconds to store the settings.

2

1

3

4

5

6

7

8

9

10

11

12

13

14

15

16

PROGRAMMING

Please Remove Card

Date and Time
DD/MM/YY HH:MM

Date and Time
DD/MM/YY HH:MM

Zero credit
No Yes

Set Credit
£XXX.XX

Emergency Credit
£XXX.XX

Emergency Credit Avail
£XXX.XX

Rate 1 Unit Cost
£XXX.XX

Rate 1 Unit Cost
£XXX.XX

Rate 1 Unit Cost
£XXX.XX

Rate 2 Unit Cost
£XXX.XX

Standing Charge
£XXX.XX

Operational Mode
Meter Timer

Factory Defaults
No Yes

Exiting Programming

7

Содержание MCM-030

Страница 1: ...ess Park Long Road Paignton Devon TQ4 7AU Tel 01803 697600 Fax 01803 697608 www rdlmeters com sales rdlmeters com Issue 1 0 USER MANUAL FOR SPECIFICATION AND OPERATING SETTINGS Issue 1 0 MAGNETIC CARD...

Страница 2: ...rs Ltd Guarantee This meter is guaranteed for a period of three years from the date of purchase subject to the following guarantee conditions This meter is covered by RDL Meters Ltd for parts and labo...

Страница 3: ...r Unit of Electricity for Rate 1 and 2 8 4 9 Standing Charge per 24 hours 8 4 10 Operation Mode Meter or Timer 8 4 11 Area Code 8 5 APPENDIX 5 1 Starting Current 8 5 2 Wiring Diagram and Mounting Temp...

Страница 4: ...Range 20 to 100A Standard Frequency 50Hz Standard 2 4 Metrology Meter Accuracy Active energy Class B 1 METER MODE 1 INTRODUCTION 1 1 Overview This manual covers the specification and operation for the...

Страница 5: ...XX X kWh registered on current tariff Rate 1 represents the current tariff The consumer has used up all credit XXXXXXX X kWh registered on current tariff The consumer has used up all credit and has ac...

Страница 6: ...1 The tariff for rate 2 kWh registered on rate 1 kWh registered on rate 2 Total kWh registered Emergency Credit If the meters prepaid credit is above this point then emergency credit is not selectable...

Страница 7: ...tanding Charge collected The Debt will also be increased by the same amount Emer Credit Left XXX XX and Current Debt XXX XX may be viewed by pressing the display button 3 6 3 Expiry When the emergency...

Страница 8: ...of a valid COMMAND CARD the following 10 parameters can be sequentially viewed modified using the RED and GREEN buttons on the meter To display modify a particular parameter first insert a COMMAND CA...

Страница 9: ...nd hold the RED button for greater than 3 seconds to store the value Press and hold the RED button for greater than 3 seconds to store the value Press and release the GREEN button until the correct va...

Страница 10: ...mergency Credit Value The emergency credit is settable in the range of 0 to 99 99 4 7 Emergency Credit Available Point The emergency credit available point is settable in the range of 0 to 99 99 4 8 C...

Страница 11: ...ate 9 METER MODE CONT Wiring Diagram and Mounting Template WIRING DIAGRAM WALL MOUNTING TEMPLATE 9 METER ACCOMMODATES SCREW SHANK UP TO 5 2MM TOP 52 52 138 MAIN LOAD PHASE PHASE NEUTRAL LINE NEUTRAL S...

Страница 12: ...Time Clock with programmable switching 13 Reverse Energy Detection 2 TECHNICAL DATA The MCM 030 is an alternating Current Static Watt Hour Meter Class B with programmable timer function facility 2 1...

Страница 13: ...ameters 3 3 Tournament Mode Override In this mode the timer dispenses electricity without the consumer needing to enter token cards DISPLAY CONTACTOR REMARKS Timer Countdown 00 00 00 Timer Countdown H...

Страница 14: ...edit is limited to 1440 minutes at which point the display will change to Maximum Reached Three examples are given below Example 1 Example 2 Example 3 3 5 2 Card Errors The message CARD ERROR may be d...

Страница 15: ...displayed parameter To store the new value press the RED button for greater than 3 seconds then on releasing the RED button the next parameter for programming will be displayed If no buttons are press...

Страница 16: ...and release the RED button for greater than 3 seconds to store the value Press and release the RED button for greater than 3 seconds to store the value Press and hold the RED button for greater than...

Страница 17: ...Maximum Reached 4 7 Tournament Mode Override In this mode the timer dispenses electricity without the consumer needing to token cards 4 8 Operational Mode Meter or Timer The timer mode setting operat...

Страница 18: ...NOTES 16...

Страница 19: ...Worle Parkway Weston Super Mare BS22 6WA United Kingdom Verified at RDL Meters Ltd Paignton Peter Gibbs Technical Director RDL Meters Ltd EC DECLARATION OF CONFORMITY RDL Meters LTD Unit E2 Westfield...

Страница 20: ......

Отзывы: