METER MODE
(cont.)
Wiring Diagram and Mounting Template
9
8
METER MODE
(CONT.)
4.2 Factory Defaults Reset
FACTORY DEFAULTS
£0.00
£1.00
£0.00
£0.00
0
£0.00
£0.15
£0.15
£1.00
£0.50
“RED” Not Displayed
DISPL
AY
Factory Defaults
No Yes
REMARKS
If Factory Defaults are reset then the following
parameters are changed:
a Current Credit
b Emergency Credit Left
c Current Debt
d Total Credit
e Total Cards
f Standing Charge per 24 hours
g Rate 1 unit cost
h Rate 2 unit cost
i Emergency Credit Value
j Emergency Credit availability point
k Reverse Energy Detection “RED” when displayed
4.3 Date and Time
The following date and time parameters are settable: Day, Month, Year, Hours, Minutes.
4.4 Zero Credit
Manually reset Debt and Credit to zero.
4.5 Set Credit
Manually set credit in the range of £0 to £999.99.
4.6 Emergency Credit Value
The emergency credit is settable in the range of £0 to £99.99.
4.7 Emergency Credit Available point
The emergency credit available point is settable in the range of £0 to £99.99.
4.8 Cost per Unit for Rate 1 and 2
The cost per unit of electricity for each of the 2 rates is settable in the range £0 to £99.99.
4.9 Standing Charge per 24 hours
The standing charge is settable in the range £0 to £99.99 and is factory set to deduct
the value set every 24 hours at midnight.
4.10 Operational Mode Meter Timer
The meter mode setting operates at cost per kWh unit of electricity or timer mode at
cost per time of electricity.
4.11 Area Code
The area code register can be factory set in the range 0-255 (Decimal).
5
APPENDIX
5.1 Starting Current
The meter starts to register at 100 mA.
5.2 Wiring Diagram and Mounting Template (shown overleaf)
The meter must be installed by a competent, qualified electrician to the standards that
satisfy the requirements of the current Institute of Electrical Engineers (IEE).
METER MODE
(CONT.)
Wiring Diagram and Mounting Template
WIRING DIAGRAM
WALL MOUNTING TEMPLATE
9
METER
ACCOMMODATES
SCREW SHANK UP
TO 5.2MM
TOP
52
52
138
MAIN
LOAD
PHASE
PHASE
NEUTRAL
LINE
NEUTRAL
RDL Meter-Timer Instruction 20/8/14 12:19 Page 9
SUPPLY
LIVE
LOAD
LIVE
SUPPLY
NEUTRAL
LOAD
NEUTRAL