Gateway connections & reporting

POS

NEG

IP1

RX

IP2

AC

TX

CID

 Input 2 / AC 

(select J1)

 DC ( ) 

+

TX

DC (-) / 

RING

  

TIP

RX

Input 1 

Input 2 jumper

With jumper 
- AC monitoring
Without jumper 
- Input 2

To panel serial

Green

Amber

Red

GSM 

activity

Input 1 

(IP1) 

 

- fixed functio

n

J1 jumper off  

- IP2 function selected

 -  Wireless panic button receiver

External resistor   - not required

Default trigger  

- positive pulse

 -  Electric fence relay output
 -  Fixed panic button

Additional hardwired inputs x2

Input 2 

(IP2/AC)

 

  - dual function 

 -  Alarm panel PGM

Input delay  

- 100ms fixed

AC delay  

- 10 minutes - fixed 

J1 jumper on 

- AC function selected 

AC function monitors mains fail/restore.

Connect 

TIP

 and 

DC(-)

 as per individual 

panel diagram for Contact ID reporting. 

Dialler capture/Contact ID

AMBER - GSM

LED Indications

Off            No GSM link

Blip            Server request (1x/3sec)
Fast flashing    Negotiating (5x/sec)
Slow flashing    Connected to server (1x/sec)

GREEN - General

RED - Server

Off            Restarting connectivity
Fast flashing    Searching for network
Variable timing  RSSI signal strength 
               - on longer = stronger
              - on shorter = weaker

Slow flashing    GSM link active
Solid          GSM network established

Off            No server connection

Battery monitoring and reporting

Reports battery low/battery restore.
Battery low  

- below 10.8V.      

Battery restored 

- above 12.5V.

Connection 

- none required

Central station software generates alert on 
polling communication failure.
Connection 

- none required

Polling/auto test

Patented “always-on” network supervision.
No auto-test/self-test reporting needed.

Содержание GSM-ICE3

Страница 1: ...allows for alarm signal reporting to the control room control of the alarm system with the smart phone app and the addition of IP cameras using the same app Smart home business IoT functions will be a...

Страница 2: ...n discover that a different panel is used on site the Dealer Admin User should be informed and the 3 correct panel type input into ICE Admin portal This input overrides selection in point 3 if differe...

Страница 3: ...TIP and DC as per individual panel diagram for Contact ID reporting Dialler capture Contact ID AMBER GSM LED Indications Off No GSM link Blip Server request 1x 3sec Fast flashing Negotiating 5x sec Sl...

Страница 4: ...8 should also be on nd 2 coms options 3 8 1 4 on Start Zone1 prog 0 0 1 Scroll to Zone7 Zone7 22 Momentary K S arm Scroll to Zone8 Zone8 01 Entry exit Entry2 delay 030 secs Exit delay 003 secs for qu...

Страница 5: ...Note Program 312 318 as 1234 if partitions 2 8 are present Com options 2 3 8 0 Install Zone7 resistor to Relay1 on the unit Away and stay arm disarm using Relay1 2 Exit and save System times 0 0 5 00...

Страница 6: ...ne8 8 Note that the exit delay need not be programmed as this will instantly arm the system in away mode Zone option K S arm disarm 5 AC AC GND GND TX Siren 12V K P Zone 7 COM Zone 8 1 2 3 4 5 Phone P...

Страница 7: ...34 Auto trouble report codes 4 0 3 7 Auto zone report codes 4 0 3 2 Contact ID format 3 0 7 0 5555 Away arm disarm using Relay1 Zone7 used as example Key switch prog type 0 5 0 3 8 dig panel serial no...

Страница 8: ...ne5 resistor to Relay1 on the unit Partition assignment 1 Enter None of the zone options should be selected Panel will instantly arm when key switch is activated Stay arming Zone4 0 0 4 Panel will ins...

Страница 9: ...no 0 1 2 x x x B C Away arm disarm using Relay1 Key switch programming 0 6 0 3 Assigned Partition1 1 Momentary key switch 1 Zone input number 0 0 7 Force arming 7 Instant arming AWAY 8 1 Second waitin...

Страница 10: ...Select Zone8 0 8 Zones7 8 used as example Away and stay arm disarm using Relay1 2 Go into programming 1 1 Key switch arm disarm 1 6 Set the zone attributes 1 5 Select Zone8 0 8 Confirm Yes arm Return...

Страница 11: ...NO 1 YES Return main screen MENU Account no NO 1234 Away arming Install Zone7 resistor to Relay1 on the unit Away and stay arm disarm using Relay1 2 Zones7 8 used as example Zone setup YES Zone7 NO S...

Страница 12: ...s the page back button twice Go to com format OK Select Contact ID OK Set zone for K S arm 1 9 OK Save and exit 0 OK Away arm disarm using Relay1 Zone7 used as example Insert installer code 1 1 1 1 OK...

Страница 13: ...ect 5 control Input format 0 4 2 0 Exit and save Go to 6 parameters Select 6 dial method Select 1 MS enable Y Select 1 DTMF Relay 1 Relay 1 Relay 2 RELAY EXPANDER GSM GATEWAY AC BUS Zone 7 COM Zone 8...

Страница 14: ...d closing and zone bypass reporting Step 6 Location 88 Away arm disarm using Relay1 Zone7 used as example Location 25 zone programming 1 8 Select segment 7 Zone7 1 1 Exit and save This will set Zone7...

Страница 15: ...TN primary all others Exit programming END repeat Set rings 1 Modify coms option for to Connect T Line Add MS2 and MS3 phone no s if used External line leave as is ENTER ACK wait time leave as is Away...

Страница 16: ...control panel and be easily accessible Telephone plugs and connectors must be installed inside the metal enclosure of the control panel Interconnecting cables must be placed in conduit Install the ga...

Отзывы: