![Rcom KINGSURO MAX 20 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/rcom/kingsuro-max-20/kingsuro-max-20_user-manual_1424125027.webp)
Troubles
Expected Causes (Possibility)
Countermeasures
In case hatching rate
is low
When a chick hatches
out earlier than
expected or a
deformed chick
hatches out
When a chick hatches
out later than
expected
When hatching dates
are so different from
each egg
(When all chicks don't
hatch out at the same
time but over a long period)
When intending to
hatching various eggs
at the same time
▶
Setting temperature too high
▶
Egg turning was not operating normally
▶
Setting temperature too low
▶
Eggs stored for different lengths of time
▶
Diffferent incubation temperatures
▶
Incubation days are different,
so hatching rate falls down.
▶
When the egg is an unfertilized egg.
▶
Getting infected by germs
▶
Wrong incubation setting
▶
Health condition of mother bird
▶
Improper egg turning
▶
Check possibility of egg
surviving
▶
Disinfect the incubator
▶
Check all settings of incubator.
Especially, check them focusing
on the temperature.
▶
Review care of health of mother bird.
▶
Check if egg turning is normal.
▶
Set limits to egg storage time properly
▶
Check Temperature difference
in the incubator.
(sunlight, temp of incubation room, etc.)
▶
Mark hatching date on eggs and
move them to other incubator
(brooder) just on the marked date.
▶
In case of putting in many eggs
at the same time, it's convenient
to prepare a spare incubator available
as a brooder
▶
Lower temp. setting of the
incubator about 0.5
℃
(1
℉
)
ex) 37.5
℃
37.0
℃
▶
Check if egg turning function is OFF
▶
Raise temp. setting of the
incubator about 0.5
℃
(1
℉
)
▶
ex)37.0
℃
37.5
℃
Frequently Asked Questions (FAQ)
Hatching result can be changed by a large number
of factors. Autoelex Co.,Ltd.
will not be held responsible for loss of eggs or chicks
under any circumstances such as hatching failure, user’s carelessness, power failure, or malfunction.
※
If the cover is not completely closed, moisture
preventing ring will not attached correctly and moisture
can be flow in the PCB part.
▶
Replace with new fuse. ( 250V 2.0A
Ø
5*20mm )
▶
Reassemble with the opposite order of disassemble.
DIGITAL INCUBATOR
27
(2) How to Replace the Fuse /
Frequently Asked Questions
6. Product Information
6. Product Information
(2) How to Replace the Fuse /
Frequently Asked Questions
USA & Canada Official Sales & Service https://www.R-Com-Hatcher.com