background image

 Total One Way  

 

 

 

      Length of 

1/4A  1/2A  3/4A  1A  1-1/4A 1-1/2A  2A 

3A

   Wire Run (ft.)
 

100  24 20 18 18 16 16 14 12

 

150  22 18 16 16 14 14 12 10

 

200  20 18 16 14 14 12 12 10

 

250  18 16 14 14 12 12 12 10

 

300  18 16 14 12 12 12 10  --

 

400  18 14 12 12 10 10  --  --

 

500  16 14 12 10 10  --  --  --

 

750  14 12 10 10 --  --  --  --

 

1000  14 10 10  --  --  --  --  -- 

 1500 

12  10 

-- 

-- 

-- 

-- 

-- 

-- 

 Total One Way  

 

 

 

      Length of 

1/4A 1/2A 3/4A  1A 1-1/4A 

1-1/2A 2A  3A

   Wire Run (ft.)
 

100  20 18 16 14 14 12 12 10

 

150  18 16 14 12 12 12 10 --

 

200  16 14 12 12 10 10  --  --

 

250  16 14 12 10 10 10  --  --

 

300  16 12 12 10 10  --  --  --

 400 

14  12  10  -- 

--  -- 

--  --

 500 

14  10  10  -- 

--  -- 

--  --

 750 

12  10  -- 

-- 

--  -- 

--  --

 1000 

10 

-- 

-- 

-- 

-- 

-- 

-- 

-- 

  1500 

10 

-- 

-- 

-- 

-- 

-- 

-- 

--  

Load Current @24V

Load Current @12V

Wire Gauge Chart courtesy of Electronic Locking Devices by John L. Schum

WIRE GAUGE SELECTIONS

7

8310 & 8320 Electromagnetic Lock

Installation Instructions 

(Continued)

Содержание 8310

Страница 1: ...rations available with this product a survey and assessment of the physical area in which the product will be installed must be performed 3 The door frame must be inspected and deemed structurally sound prior to installation of the electromagnetic lock The structural integrity of the mounting surfaces must be strong enough to meet or exceed the holding force of the product 4 The product must be pr...

Страница 2: ...inal of the lock in Fig 2 Switching the negative power supply line will not allow the lock to release immediately RCI electromagnetic locks contain MOV s for surge suppression and do not require any additional suppression to be added during installation The installation of diodes across the lock input terminals will cause a delay in release Fig 2 Power Connections SWITCH INCORRECT CORRECT SWITCH F...

Страница 3: ... at the bolt There should be no movement to the mounting bracket or housing of the electromagnetic lock For added safety thread locking compound has been provided for the armature plate bolt and the four captive electromagnetic lock mounting screws WARNING Improper installation maintenance inspection or usage of the product or any related accessories or parts may cause the electromagnetic lock arm...

Страница 4: ...cted releasing devices lock terminals and lock circuit board to magnet core Check delayed relock wiring and time setting Check that the momentary switch does not include a shunted light option Lock has enough holding force to lightly hold a screwdriver or set of pliers but door will not lock Check to see that armature plate is correctly aligned with the electromagnetic lock If there is improper al...

Страница 5: ...ere there is insufficient frame depth to mount the lock Available in several different sizes and finishes L Bracket Required wherever there is insufficient space on the frame header to mount the lock The lock mounts to the underside of the L bracket and the L bracket then gets mounted to the doorframe Available in several finishes Glass Door Bracket Allows an armature plate to be mounted to a glas...

Страница 6: ...ide extra mounting space in a hollow metal or wood frame where the door stop of the frame is not thick enough to allow a lock to be installed Available in several different heights and widths Spacer Bars For use when an obstruction in the door prevents the installation of the armature plate at a proper height If the armature plate needs to be lowered then a spacer bar can be used to lower the lock...

Страница 7: ...10 1000 14 10 10 1500 12 10 Total One Way Length of 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A Wire Run ft 100 20 18 16 14 14 12 12 10 150 18 16 14 12 12 12 10 200 16 14 12 12 10 10 250 16 14 12 10 10 10 300 16 12 12 10 10 400 14 12 10 500 14 10 10 750 12 10 1000 10 1500 10 Load Current 24V Load Current 12V Wire Gauge Chart courtesy of Electronic Locking Devices by John L Schum WIRE GAUGE SELECTIONS 7 ...

Страница 8: ...CATION DATE NOTES INITIAL 8310 8320 Electromagnetic Lock Installation Instructions Continued 2017 Rutherford Controls Int l dormakaba Group www rutherfordcontrols com Phone 1 800 265 6630 Fax 1 800 482 9795 E mail sales rutherfordcontrols com ...