RCF MH 61EN Скачать руководство пользователя страница 5

5

ENGLISH

IMPORTANT NOTES

WARNING

SAFETY AND OPERATING 

PRECAUTIONS

Before connecting and using this product, please read this user manual carefully and keep it on 
hand for future reference. This manual is to be considered an integral part of this product and must 
accompany it when it changes ownership as a reference for correct installation and use as well as for 
the safety precautions.
RCF S.p.A. will not assume any responsibility for the incorrect installation and / or use of this product.

SAFETY AND OPERATING PRECAUTIONS
1. 

All the precautions, in particular the safety ones, must be read with special attention, as they 

provide important information.

2.

 Speaker lines (amplifier outputs) can have a sufficiently high voltage (i.e. 100-70 V) to involve a risk 

of electrocution: never install or connect this speaker when the line is alive.

3.

 Make sure all connections have been made correctly and the speaker input voltage is suitable for 

the amplifier output.

4. 

Protect speaker lines from damage. Make sure they are positioned in a way that they cannot be 

stepped on or crushed by objects.

5.

 Make sure that no objects or liquids can get into this product, as this may cause a short circuit.

6. 

Never attempt to carry out any operations, modifications or repairs that are not expressly described 

in this manual. 
Contact your authorized service centre or qualified personnel should any of the following occur:

 

- The speaker does not function (or works in an anomalous way).

 

- The cable has been damaged.

 

- Objects or liquids have got into the speaker.

 

- The speaker has been damaged due to heavy impacts or fire.

7. 

Should the speaker emit any strange smell or smoke, remove it from the line after having immediately 

switched the amplifier off.

8.

 Do not connect this product to any equipment or accessories not foreseen.

For suspended installation, only use the dedicated anchoring points and do not try to hang this speaker 
by using elements that are unsuitable or not specific for this purpose.
Also check the suitability of the support surface to which the product is anchored (wall, ceiling, 
structure, etc.) and the components used for attachment (wall plugs, screws, brackets not supplied by 
RCF, etc.), which must guarantee the security of the system / installation over time, also considering, 
for example, the mechanical vibrations normally generated by transducers.

9. RCF S.p.A. 

strongly recommends this product is only installed by professional qualified installers 

(or specialised firms) who can ensure a correct installation and certify it according to the regulations 
in force.
The entire audio system must comply with the current standards and regulations regarding electrical 
systems.

10. 

Mechanical and electrical factors need to be considered when installing professional audio 

systems (in addition to those which are strictly acoustic, such as sound pressure, angles of coverage, 
frequency response, etc.).

11. 

Hearing loss

Exposure to high sound levels can cause permanent hearing loss. The acoustic pressure level that leads 
to hearing loss is different from person to person and depends on the duration of exposure.
To prevent potentially dangerous exposure to high levels of acoustic pressure, anyone who is exposed 
to these levels should use adequate protection devices.
When a transducer capable of producing high sound levels is being used, it is necessary to wear ear 
plugs or protective earphones.
See the technical specifications in this user manual to know the maximum sound pressure this speaker 
is capable of producing.

Содержание MH 61EN

Страница 1: ...USER MANUAL MANUALE D USO MH 61EN TWO WAY HORN SPEAKER IN COMPLIANCE WITH EN 54 24 STANDARD DIFFUSORE ACUSTICO A TROMBA A DUE VIE CONFORME ALLA NORMA EN 54 24...

Страница 2: ......

Страница 3: ...ALLATION NOTES ABOUT CONSTANT VOLTAGE SYSTEMS SPECIFICATIONS ITALIANO AVVERTENZE PER LA SICUREZZA DESCRIZIONE COLLEGAMENTO INSTALLAZIONE NOTE GENERICHE SUI SISTEMI A TENSIONE COSTANTE DATI TECNICI 5 7...

Страница 4: ......

Страница 5: ...ve it from the line after having immediately switched the amplifier off 8 Do not connect this product to any equipment or accessories not foreseen For suspended installation only use the dedicated anc...

Страница 6: ...s should not be laid together with other electric cables mains microphone or line level signal cables connected to amplifier inputs 14 The speaker cable shall have wires with a suitable section twiste...

Страница 7: ...stems having large spaces for instance supermarkets railway stations undergrounds factories warehouses etc and also in all environments that need high efficiency speakers WARNING speaker connections s...

Страница 8: ...y connect in the same way the output cable passing it through the other rear cover guide to link other speakers in parallel INTERNAL TRANSFORMER POWER TAPPING The internal transformer is connected to...

Страница 9: ...maged parts that could reduce the safety of the installation This speaker can be installed both indoors and outdoors IP 66 1 Fix the mounting bracket only to the wall with screws and wall plugs throug...

Страница 10: ...equate cross section considering the cable length and the total speaker power Speaker lines must be kept separated from mains cable microphone cables or others in order to avoid inductive phenomena ma...

Страница 11: ...ICAL SPECIFICATIONS Speaker material Bracket material Colour Connector IP protection grade Net weight Dimensions w h d 100 Hz 20 kHz 99 dB 1 W 1 m 87 dB 1 W 4m 115 dB 60 W 1 m 103 dB 60 W 4 m 70 90 6...

Страница 12: ...diffusore provengano odori anomali o fumo spegnere immediatamente l amplificatore relativo alla linea e poi scollegare il diffusore 8 Non collegare a questo diffusore apparecchi ed accessori non previ...

Страница 13: ...iffusori non devono essere canalizzate insieme ai conduttori dell energia elettrica ai cavi microfonici alle linee di segnale a basso livello che fanno capo ad amplificatori 14 Il cavo per il collegam...

Страница 14: ...izzo in sistemi audio dove sono presenti grandi aree quali ad esempio supermarket stazioni ferroviarie metropolitane fabbriche magazzini ecc ed anche in tutti quegli ambienti dove richiesta un alta ef...

Страница 15: ...allo stesso modo il cavo d uscita attraverso l altro passacavo destinato alla connessione in parallelo di altri diffusori acustici SELEZIONE POTENZA NEL TRASFORMATORE Il trasformatore interno collegat...

Страница 16: ...mancanti o danneggiate che possono ridurre la sicurezza dell installazione Il diffusore acustico pu essere installato sia in ambienti chiusi sia all aperto grado di protezione IP 66 1 Fissare la sola...

Страница 17: ...la potenza complessiva dei diffusori acustici Per evitare che fenomeni induttivi diano luogo a ronzii disturbi e compromettano il funzionamento del sistema i cavi per i diffusori acustici non devono e...

Страница 18: ...Protezione DATI FISICI Materiale del corpo Materiale della staffa Colore Connettore Grado di protezione IP Peso netto Dimensioni l h p 100 Hz 20 kHz 99 dB 1 W 1 m 87 dB 1 W 4m 115 dB 60 W 1 m 103 dB 6...

Страница 19: ...anzio 13 42124 Reggio Emilia ITALY 18 1488 CPR 0672 W EN 54 24 2008 MH 61EN Type B DoP 002_18 Other technical data see operational manual Loudspeaker for voice alarm systems for fire detection and fir...

Страница 20: ...milia Italy Tel 39 0522 274 411 Fax 39 0522 232 428 e mail info rcf it Salvo eventuali errori ed omissioni RCF S p A si riserva il diritto di apportare modifiche senza preavviso Except possible errors...

Отзывы: