16
4. CABLING
Description of the cabling to be made between DXT 3000 units connected in INTERLINK mode.
4.1. BUS INTERLINK
2 x CJ428CAT CABLES are needed for each connection between DXT 3000 units (redundant connection). The
INTERLINK Bus connections will be done on the IT 3010 boards of all DXT 3000 unit (IE 3008 if IT 3010 are not
installed).
It must not be completed the “ring connection” from the last SLAVE unit to the MASTER unit. The MASTER unit
is always the first DXT 3000 unit of the INTERLINK Chain.
EXAMPLE WITH 2 DXT 3000 UNITS
•
MASTER unit: only ITL OUT A/B.
•
SLAVE unit: only ITL IN A/B.
EXAMPLE WITH 4 DXT 3000 UNITS
•
MASTER unit: only ITL OUT A/B.
•
Intermediate SLAVE unit: ITL IN A/B and ITL OUT A/B.
•
Last SLAVE unit in chain: only ITL IN A/B.