RBM PAD INDOO Скачать руководство пользователя страница 7

7

MORE PAD INDOOR

2.4 GENERAL INFORMATION

2.5 GENERAL INFORMATION ON LOGISTICS

• 

PAD INDOOR is an electric radiant heating 

system;

• 

PAD INDOOR consists of a thin mat, 

electrically powered at very low voltage, 

that self- modulates electrical consumption 

and self- adjusts maximum surface 

temperature;

• 

PAD INDOOR is not an amorphous thin film 

extruded resistor in cable, traditional or 

carbon conductor;

• 

The heating of the mat takes place 

thanks to the molecular vibration of 

the technopolymer making up the 

semiconductor mat;

• 

Thermal expansion of the nanoparticles 

gradually reduces electrical absorption, 

thereby self-limiting the surface 

temperature;

• 

Heated surfaces do not run the risk of 

overheating when covered;

• 

The maximum surface temperature is 

compatible with the surface temperature 

limits of the flooring currently in force (UNI 

EN 1264);

• 

PAD INDOOR is a radiant system that can 

be combined with very low inertia finishes, 

with final thicknesses limited to just 15 mm 

(dry finish with plasterboard wall panel, 

or application of ceramic coating with 

bonding);

• 

The response times of the PAD INDOOR 

system are the same as those of a similar 

hydronic radiant system, and depend on 

the mass to be energised and the average 

starting radiant temperature. Normally, in 

a residential environment, the wait for the 

design surface temperature to be reached 

is about 15...20 minutes for a very low inertia 

finish;

• 

The PAD INDOOR system, like any radiant 

system, must provide for the interruption of 

heat conduction in the direction opposite 

to the radiant transfer into the room. For 

this reason, it is essential that the surface 

on which the system will be installed is 

adequately insulated. If there are no specific 

requirements, provide an insulating layer 

of at least 20 mm EPS from the rest of the 

building envelope;

• 

The mat is produced in 30-metre rolls, each 

of which is tested to verify the nameplate 

power consumption;

• 

Check that the boxes have not been 

damaged, are not wet or damp and above 

all that they do not have a manufacturing 

date prior to 5 years from the year of 

installation;

• 

hen opening the package, avoid using 

blades or cutters to avoid unintentionally 

cutting into the product contents;

• 

Protect against UV radiation (like all 

polymers it is photosensitive);

Содержание PAD INDOO

Страница 1: ...INSTRUCTION MANUAL MI3857_01 MORE PAD INDOOR ELECTRICAL INDOOR RADIANT HEATING SYSTEM MORE PAD INDOOR...

Страница 2: ...ressive heating of the semiconducting polymer As the temperature of the mat increases the nanoparticles contained in the polymer compound move away from each other resulting in a progressive decrease...

Страница 3: ...tion Plastering with water based cement mortar that can be smoothed over reinforcement mesh Ceramic wall tiles glued onto levelling compounds Dry application of plasterboard Integration of domestic he...

Страница 4: ...ng system Check that the power supply is adequately protected as described in the following Chapter 9 PAD INDOOR system installation Before installation make sure that the electrical system if any has...

Страница 5: ...cal circuit regarding ordinary or extraordinary maintenance operations must be carried out by professionally specialised personnel authorised according to Italian Ministerial Decree 37 2008 Refrain fr...

Страница 6: ...uce consumption as it has reached its natural self regulating limit of approximately 30 C Self modulation depends on the semiconductor material and is limited to maximum 50 of initial consumption ther...

Страница 7: ...ceramic coating with bonding The response times of the PAD INDOOR system are the same as those of a similar hydronic radiant system and depend on the mass to be energised and the average starting radi...

Страница 8: ...Avoid contact with solvents as well as with glues and two component mortars that could compromise the long term stability of the technopolymer The surface of the mat can be covered with any type of b...

Страница 9: ...RBM MORE advanced thermoregulation system associate the PAD INDOOR system with the control of window opening as well as the remote function control APP The control drivers included in the PAD system...

Страница 10: ...ght IP65 SELV 3858 A Feeder to control very low voltage current modulating utilities with constant output voltage 230VAC 36VDC Power output 600 W watertight IP65 SELV 3858 B Feeder to control very low...

Страница 11: ...for starting load limitation YES Remote on off consent YES Working environment temperature 40 70 C Max ambient working temperature peaks 90 C Dimensions LxDxH 252x90x43 8 mm Feeder weight 1 9 kg Mat...

Страница 12: ...S Working environment temperature 40 55 C Max ambient working temperature peaks 90 C Dimensions LxDxH 280x144x48 5 mm Feeder weight 3 9 kg DRIVER of power supply 1000W Electrical power supply 90 264 V...

Страница 13: ...n assisted heat output NO At nominal heat output elmax 0 035 kW Type of heat output room temperature control indi cate only one option At minimum heat output elmax 0 035 kW single stage heat output wi...

Страница 14: ...without a heating system as a result of the non invasive work required The very low thermal inertia of the radiant element allows for fast system adjustments The heating element can be applied with a...

Страница 15: ...n the case of the installation of heating systems equipped with radiant floor or ceiling panels and in the case of insulation from the inside the minimum heights of the living quarters provided for in...

Страница 16: ...bicles 6 3 REGULATORY INFORMATION Special environments and applications IEC standard 64 8 part 7 Bathrooms have special environmental conditions that lead to greater risks especially related to the po...

Страница 17: ...from the building envelope in the same way as any radiant air conditioning system This requirement is supplementary to any thermo technical dimensioning related to the energy efficiency of the buildin...

Страница 18: ...lly placed in non heated or frost free conditions The chart below shows the self adjusting capacity of the technopolymer as the contact temperature of the mat changes PAD INDOOR TEMPERATURE C OUTPUT V...

Страница 19: ...ed with the dimensioning of the extra low voltage power lines the cable route must be as short as possible in order to limit voltage drop as much as possible For the DC extra low voltage line provide...

Страница 20: ...less of the size of the rooms and the electrical power installed the electrical system to be built must always be preceded by the project drawn up as provided for by Italian Ministerial Decree 37 2008...

Страница 21: ...cated lacks or has limited ventilation for the correct operation of the equipment false ceiling built in electrical box etc A maximum of 10 m of PAD mat must be fed When the heating system is installe...

Страница 22: ...nvironment where SELV safety is required When the heating system is installed in a special environment where SELV safety is required such as wet rooms or bathrooms A C B D C B D A IN line power supply...

Страница 23: ...connection Use one or more terminals bridged bridged Remote consent ON OFF Closed contact ON Output voltage adjustment trimmer highlighted in red 1 V 8 GND 4 V 6 V 2 AC N 2 PV DIS 2 V 13 Vccs 5 V 3 7...

Страница 24: ...referable not to place the power supply in quiet areas or within partitions separating bedrooms or reading rooms Avoid anchoring power supplies on large surfaces that can transmit vibrations Although...

Страница 25: ...ngth specified in the installation plan Position the strings according to the centre distances specified in the installation plan When laying on the floor lay an electrical cable duct along the side c...

Страница 26: ...t coloured cord for the extra low voltage line use red and black so that the two uprights and their polarities can be easily distinguished Mark the wire pair with an identification number so that it c...

Страница 27: ...y cords of the mats with the backbone coming from the driver this must always be located in zone 3 If the power supply driver with SELV protection is not used the PAD INDOOR system can still be instal...

Страница 28: ...se overall length does not exceed the maximum length of 7 metres It is possible to wire several strings of PAD INDOOR in SERIES PARALLEL whose overall length does not exceed the maximum length of 7 me...

Страница 29: ...opted in the event of an excessive voltage drop being detected junction box for changing the cross section of the power cable electrical upright for con nection to power drivers example strings max le...

Страница 30: ...check that all strings are uniformly at temperature primary circuit driver input voltage control 230 V AC driver output voltage control sub circuit 36 0 V DC secondary circuit voltage control to junc...

Страница 31: ...of the braid on the upright at the cut point Do not use any other type of tape as too aggressive thinners may lead to deterioration of the polymer forming the heating mat The self amalgamating double...

Страница 32: ...from sagging For the installation steps and instructions follow the guidelines given by the manufacturer of the screed and the installer of the surface finish the thickness of the self levelling agen...

Страница 33: ...terminals it is advisable to remove part of the PAD INDOOR support surface at the crimping area of the electrical terminal so that it does not generate thickness If the wall does not allow electrical...

Страница 34: ...this end of life equipment was originally paid for by the manufacturer organised and managed by the manufacturer The user who wishes to dispose of the equipment included in this system should therefor...

Страница 35: ...ave BS Italy P IVA 00551250988 RBM spa reserves the right to improve and change the products described and relevant technical data at any moment and without prior notice The information and images con...

Отзывы: