33
MORE PAD INDOOR
Valid for the wall and/or ceiling
Plasterboard finish
The string centre distance will depend on the
peak thermal power to be delivered; if there are
no specific requirements, it is advisable to ensure
a longitudinal centre distance of approximately
400 mm (axis-axis), a measurement that matches
the majority of metal counter spreader structures
(structure present in the case of false ceilings).
In order to prevent the formation of bumps and
bulges on the final surface of the plasterboard
caused by the passage of cables and crimping
terminals, it is advisable to remove part of the PAD
INDOOR support surface at the crimping area of
the electrical terminal so that it does not generate
thickness.
If the wall does not allow electrical cables to be
passed inside the false wall or ceiling (laying
close to the “sandwich” sheet), it is advisable to
remove a strip of plasterboard of about 50 mm
to accommodate the crimping area as well as to
facilitate passing the electrical cables.
Once the electrical wiring and functional test have
been completed, finish by laying plasterboard
counter-sheets to hold the PAD INDOOR strings
inside the “sandwich”.
Ensure perfect adherence between the PAD
INDOOR and the counter-slab by correctly
anchoring the latter to the spreader structure or the
floor.