11
Pulse Mode Selection -
Provides parameters for Pulse Width and Pulse Frequency in DC Pulse Tig Mode.
Pulse Frequency: Select by push-
ing selector pad to cycle through to
illuminate the Hz Pulse icon.
Rotate the Adjustment Encoder
Knob to set the Pulse Frequency
(Range is 0.5 - 200 Hz).
The value selected is shown in the digital
display. The value selected is the amount
of pulses per second (Hz)
Pulse Width: Select by pushing
selector pad to cycle through to
illuminate the % Pulse icon.
Rotate the Adjustment Encoder
Knob to set the Pulse Width
(Range is 10 - 90%).
The value selected is shown in the digital
display. The value selected is the % of on
time of the Peak Amp during each pulse.
Turn the Encoder to set
the Peak Amp value
(Range is 10-200A)
Base Amp: Select by pushing selector
pad to cycle through to illuminate the Peak
Amp icon.
The value selected shows on the digital
display. It is the amount of amps the
machine will deliver at the finish of the
welding sequence.
Finish Amp -
Provides selection for the amount of amps required at the end of the weld.
Down Slope Time -
Sets the transition time from Welding Amperage to Finish Amperage
Turn the Encoder to set
the Up Slope value
(Range is 0-60 Sec)
The value selected shows on the digital
display. It is the amount of time it takes
for the welding amperage to drop down
to the set Finish Amperage.
Continued - Front Panel Operation - Weld Program Sequence Control
Up Slope Time: Select by pushing selector
pad to cycle through to illuminate the
Up Slope icon.
Post Gas Timer -
Provides selection for continued gas flow time at the end of the welding after the arc is out.
Turn the Encoder to set
the Post Gas Time
(Range is 0-10 Sec)
Pre Gas Time: Select by pushing selector
pad to cycle through to illuminate the
Post Gas Timer icon.
The value selected shows on the digital
display. It is the length of time the gas
will flow after the arc is finished.
Torch Switch Mode Selection -
Provides a choice of Torch Switch control sequence.
2T: Select by pushing
selector pad to cycle through to
illuminate the 2T icon.
2T Selection provides 2 times function of the torch switch.
(1) Pressing the torch switch gives arc ignition and initializes the welding sequence,
the welding current is maintained by the torch switch being held on.
(2) Releasing the torch switch stops the welding sequence by introducing down slope,
the current falls to minimum level and then terminates the welding current and
introduces the post flow gas.
2T -
Selection provides 2 times function of the torch switch.