SAFETY INFORMATION
DO NOT attempt to operate this equipment until you have read and understand the
potential hazards associated with operating this equipment and are able to follow all
safety and operating procedures found in the safety manual and this operation manual.
Potential hazardous situations are identified whenever you see the following alert:
! WARNING
3.0
OPERATING INSTRUCTIONS
! NOTICE
10/4/2010 (9:19 AM)
2034 - 3 - Operation v4.05
When a ball valve handle is parallel to the valve or
pluming, the valve is wide open. When a ball valve
handle is perpendicular to the valve, it is completely
closed.
OPEN
CLOSED
3.1
Pressure Pot Settings:
The Pressure Pot
has two adjustment ball valves that can regulate the
abrasive/air flow mixture. The standard settings for
the pressure pot should be made as follows:
3.1.1
Set Abrasive Flow Valve (D) at approximate
half way open or approximately 45° angle.
Abrasive
45º
Air Flow
45º
Set Air Flow Valve (B) approximately half way
open or at 45° angle. Adjustments will need to be
made as wear occurs to Blast Hose (K) and Blast
Nozzle (T).
! NOTICE
Abrasive Flow Valve (D) usually does not require
adjustments from the 45 degree position unless
there are drastic pressure changes, or larger nozzle
orifices are used.
3.2
Connecting Air to Cabinet
3.2.1
Before connecting the air hose from the
compressor to the pot, make sure the Air Inlet Valve
(C) is in the “OFF” position (horizontal) and the air
compressor has been set up according to
instructions found in the Rayzist setup guide.
3.2.2
Connect the compressor air hose to the Air
Inlet Valve Quick Disconnect Plug (N) but DO
NOT turn the air inlet valve (C) to the on position
yet.