COMPASS
STD22
Change Over Box
138--119
27
3769DOC000002
Edition: April 06, 2005
The used Magnetic Sonde has to be a Twin Magnetic Sonde. It means: Each Compass
system has to have an independent Magnetic Sonde.
If an error occurs in the DU1 of the compass system1, the DU 1 generates an error mess-
age “System Failure” , in terms of a 24 V DC switch potential, to the Change Over Box.
In the automatic mode this “System Failure” effects a switching--over from the outputs of
DU 1 to the outputs of DU 2.
The STD22 GGM--R Gyro Compass System is equipped with a redundant power supply
(see section 4.3 Redundant Voltage Supply).