GP Monitor
6
Rev. F 10/2011
GP Series
Setpoints:
Head type H001:
-18 to 538°C (0 to 1000°F)
Head type H003:
0 to 500°C (32 to 932°F)
Head type H004:
0 V input setting = low scale,
5 V input setting = high scale
Head type H005:
4 mA input setting = low scale,
20 mA input setting = high scale
Head type H006:
scale = input thermocouple range:
J-type:
-40 to 750°C (-40 to 1382°F)
K-type: -40 to 1250°C (-40 to 2282°F)
E-type:
-40 to 700°C (-40 to 1292°F)
N-type: -40 to 1300°C (-40 to 2372°F)
R-type: 0 to 1750°C (32 to 3182°F)
S-type:
0 to 1750°C (32to 3182°F)
T-type: -100 to 350°C (-148 to 662°F)
Head type H007:
-40 to 1650°C (-40 to 3002°F)
(depending on model)
4 mA input setting = low scale,
20 mA input setting = high scale
3.1.2
Electrical Specifications
Voltage:
110 – 220 VAC + 20 %, 50 – 60 Hz, 100 mA
Current output:
4 to 20 mA
Max. loop impedance:
350
2 Setpoints output:
CMOS level Hi/Lo (5 V / 0 V)
GPC Monitor
SP1, SP2: 15 mA @ 5 V
Mechanical Relay:
AC contact: 250 VAC, 3 A
GPCM Monitor
DC contact: 30 VDC, 3 A
3.1.3
Environmental Specifications
Dimensions:
1/8 DIN, 118 mm length
(1.75 x 3.63 x 4.75 in)
Weight:
320 g (0.7 lbs)