Installation
Go
to
the
menu
<Setup>
<Sensor
Setup>,
and
then
select
the
register
<Advanced
Setup>.
Use
<Polling
Address>
for
selecting
the
requested
address.
Figure
23:
Address
Setting
Step
‐
by
‐
step
instructions
for
addressing
RS
‐
485
MI
units:
1.
Power
the
unit.
2.
Using
either
the
buttons
or
software,
assign
unique
address
to
the
sensor.
3.
Power
down
the
unit.
4.
Repeat
until
all
sensors
have
a
unique
address.
5.
On
the
last
unit
in
the
network,
activate
the
shunt
resistor
after
the
unit
has
been
powered
down.
Failure
to
use
shielded
RS
‐
485
wire
or
activation
of
the
shunt
resistor
when
the
unit
is
powered,
can
result
in
damage
to
the
electronics!
MID
33