Installation Steps: 

1

.

VARIO2  is factory set and delivered with a 35˚

beam width.
To alter to 10˚, simply remove interchangeable
lens (ILS). See page 4 for detailed instructions
To alter to 60˚, replace with other ILS lens
supplied.

2. Mount Illuminator
3. Connect Illuminator to low voltage input 12-24V

AC/DC (For Vario 16 variants : 24V AC or DC only)

4-6. Complete configuration, wiring and final  set-up using manual push
buttons on the illuminator or VARIO Remote Controller (VRC)

- VRC is  an optional accessory

The external cable cannot be replaced. If it is damaged and the customer 
is unable to shorten and re-use the cable, the illuminator must not be 
powered. 

Wiring – six core cable 

White & Yellow wires = 
Photocell following contact, 
Volt free output, Non polarity sensitive 

Orange and Purple Wires = 
Telemetry input Volt free / dry contact or 
TTL input (see Page 5 and 6  for more detail) 

    DC 

 AC 

Black Wire -

~

Red Wire  

+

~

Photocell 

Cable 

Breather 

Gland

 

2  

Box Contents :

 VARIO2 Illuminator , spare 60° beam angles ILS 
 (ILS: Interchangeable Lens  System)  
Accessories (Optional) :VARIO Remote Control for additional Programming; 

80˚ beam and 120˚ beam angle ILS; Bracketry 

VARIO2  Enhancements 

Increased Distance

Default time for illuminator to go into Operating Mode reduced

PIN function for enhanced security

Manual Control added – Push Buttons Accessible on the illuminator

Improved RESET Options

The 3 single colour feedback LED’s have been replaced with
2 tri-colour LED’s

Safety Information 

Eye Safety : IR Variants (850nm and 940nm) 
Caution – IR emitted from this product  EN62471 Risk Group 2 
Do not stare at the lamp. Avoid exposure or use appropriate 
shielding / eye protection. Risk Group 2 for cornea / lens 
infrared hazard. For VAR-i2, VAR-i4, VAR-i6 and VAR-i8 
variants hazard distance is 1500mm. For VAR-i16 hazard 
distance is 1840mm. Max IR EHV (Exposure Hazard Value) : 
69% of Risk Group 2 Limit at 200mm from the lamp. 

Eye Safety : White Light and 730nm variants

 

Caution – EN62471 Risk Group 2 Classification -  Possible 
hazardous optical radiation emitted from this product. May 
be harmful to eyes, do not stare at the lamp. For VAR-w2, 
VAR-w4, VAR-w8 Hazard distance is 1500mm. For VAR-w16 
hazard distance is 1840mm. Max WL EHV (Exposure Hazard 
Value) : 68% of Risk Group 2 Limit at 200mm from the lamp. 

Eye Safety: Other Wavelengths - Contact Raytec. 

The Illuminator is Class lll  for insulation 

Illuminators are suitable for use Outdoors and  Indoors 

Содержание VARIO2 VAR2-i2-1

Страница 1: ...ed Photocell sensitivity MID Status LEDs ON No PIN Set Unit will change from Programming Mode to Operating Mode after 7 Days or 30 minutes after last press of manual buttons Timer Disabled VARIO2 Spec...

Страница 2: ...plate at the bottom of the unit The number of button pushes indicated below are based on the user starting with the illuminator in either programming or operating mode Action Required Step1 LHS Button...

Страница 3: ...two modes 1 Programming Mode when the remote control can be used and 2 Operating Mode when most of the remote control functions are disabled The only remote control functions that can be used in Oper...

Страница 4: ...rmittent Flashing Red Green Solid Amber to Flashing Red Flash qty counts down the No of characters required After PIN deleted Illuminator goes to Programming Mode Standard LED indication For full PIN...

Страница 5: ...rking Cover photocell fully light should turn on if valid telemetry input It is sometimes difficult to see Infra Red illuminators working in high brightness conditions Ensure power supply is suitably...

Страница 6: ...eam and 120 beam angle ILS Bracketry VARIO2 Enhancements Increased Distance Default time for illuminator to go into Operating Mode reduced PIN function for enhanced security Manual Control added Push...

Страница 7: ...mplete Set up and Installation Step 1 Select different beam angle if required To alter to 10 simply remove interchangeable lens ILS To alter to 60 replace with other ILS lens supplied Other angle ILS...

Страница 8: ...control and buttons are available in Programming Mode The only function of the Remote Control available during Operating Mode is LED Status Indicators Enable Disable entering a PIN or disabling manua...

Страница 9: ...ble manual buttons must be done within 5 minutes of remote disable 9 Extra VRC Functionality PIN Function For extra security VARIO2 allows a PIN Personal Identification Number to be set for each lamp...

Страница 10: ...ough Note invalid characters will not be recognised To create a PIN press STATUS BUTTON for 4 seconds LHS LED will flash RED GREEN This indication will always show that you are in PIN mode RHS LED FLA...

Страница 11: ...gs Power Level Photocell sensitivity Indicator LED status On or Off A continuous 4 second press of the LHS button turns LHS LED flashing RED and enters the user into the Illuminator Security Modes In...

Страница 12: ...e pressed within 2 minutes the Illuminator times out and returns to the previous mode it was in either operating or programming mode 14 Manual Setting Level Indication using RHS Button The RHS BUTTON...

Страница 13: ...Manual Button Control Solid RED Note If the illuminator is in Operating Mode and the buttons are currently disabled you cannot re enable 17 NOTE If no buttons are pressed within 2 minutes the illumin...

Страница 14: ...sed in either Illuminator Settings Modes or Illuminator Configuration Modes the Illuminator will default into Operating Mode 30 minutes after the last button press RESET Options There are Two Re set o...

Страница 15: ...and correctly wired 20 VARIO2 Specifications Table Infra Red Series White Light Series i16 w16 i8 w8 i6 i4 w4 i2 w2 10 500m 1640ft 250m 820ft 350m 1148ft 180m 591ft 200m 656ft 144m 472ft 110m 361ft 78...

Страница 16: ...tion to ensure required distance is achievable Check unit is set to max power Check orientation of unit and ensure it is pointing in correct direction Check angle of unit Interchangeable lens Too narr...

Страница 17: ...10 17 Raytec Global excluding Americas Tel 44 0 1670 520055 Fax 44 0 1670 819760 sales rayteccctv com Americas Tel 1 613 270 9990 Toll Free 1 888 505 8335 ussales rayteccctv com www rayteccctv com Ver...

Отзывы: