Remote Control Operation 
PIN set and  Manual Button Disable / Enable 

Action 

Required 

Available 

Mode 

Step1 

Step 2 

LHS 

LED 

RHS 

 LED 

Comment 

Disable 
Remote 

Programming 
Mode 

Press 
<Disable 
Remote 
Control> 
button on 
VRC for 4 
seconds 

N/A 

Solid Green 

Flashing Amber to 
Solid Amber to Off 

Illuminator will go 
to Operating 
Mode. RHS LED 
turns Off when in 
Operating Mode. 

Disable 
Manual 
Buttons 

Operating 
Mode 

Press 
<Disable 
Remote 
Control> 
button on 
VRC for 4 
seconds 

N/A 

Solid Green – 
After 4 
seconds 
Flashing Red 

(Returns to 
Solid Green 
after button 
release) 

Off to Solid Amber, 
then  after 4 
seconds Flashing 
Red 

(Returns to Solid 
Green after button 
release) 

Must be done 
within 5 minutes 
of Disabling 
remote (as 
above) Change 
will take effect 
after 30 minutes 

Create or 
Change 
PIN 

Programming
Mode 

Press 
<Status 
Button> 
for 4 
seconds 

Enter 

valid PIN 

charact

ers 

 x 4 

Green to 
Intermittent 
Flashing Red / 
Green  

Solid Amber  to 
Flashing Red  
Flash qty counts 
down the No. of 
characters 
required. 

After PIN created 
Illuminator goes 
to Programming 
Mode (Standard 
LED indication) 

Enter 
existing PIN 

Operating 
Mode 

Press 
<Status 
Button> 
for 4 
seconds 

Enter 

valid PIN 

charact

er 

 x 4 

Green – 
Intermittent 
Flashing Red / 
Green  

Solid Amber to 
Flashing Green 
Flash qty counts 
down the No. of 
characters 
required 

If invalid PIN 
entered both 
LEDs flash red and 
unit will stay in 
Operating Mode 

Delete PIN  Programming 

Mode 

Press 
<Status 
Button> 
for 4 
seconds 

Press 
<Re-Set> 
button 4 
times 

Green – 
Intermittent 
Flashing Red / 
Green  

Solid Amber to 
Flashing Red Flash 
qty counts down 
the No. of  
characters 
required  

After PIN deleted 
Illuminator goes 
to Programming 
Mode (Standard 
LED indication) 

For full PIN function detail (inc valid PIN characters) – see FULL instruction 

guide 

LED Status Indicators: 

Programming Mode and Operating Mode 

On first power up (Factory Default) the illuminator  automatically enters 

Programming Mode. It will then time out automatically after 7 Days to Operating 

Mode unless the user actively disables the remote control or uses the manual 

buttons in which case Operating Mode will start 30 minutes after the last manual 

button press. The LED Indicators feedback the mode you are in. (They are also 

used for PIN or Manual Button Control Modes – please see tables / FULL Instruction 

Manual) 

During Programming Mode and Operating Mode the two LED’s indicate the 

following status : 

LHS SOLID GREEN:

Power Applied 

LHS FLASHING GREEN:

Remote control IR received problem  

RHS FLASHING AMBER:

Indicates unit is in programming mode 

(Programming Mode Only) 

RHS SOLID AMBER:

Indicates that a valid command is being received 

(Programming Mode Only) 

LHS FLASHING RED:

  Voltage supply problem detected 

LHS SOLID RED:

  Illuminator LED fault detected 

All functions of the remote control and buttons are available in Programming 

Mode.   

The only function of the Remote Control available during Operating Mode is  

LED Status Indicators Enable/Disable, entering a PIN or disabling manual buttons 

(if done at the same time as disabling the remote – see FULL Instruction Manual  

Left hand side 
(LHS) Button 

Right hand side 
(RHS) Button 

Left hand side 

(LHS) LED 

Right hand side 
(RHS) LED 

Содержание VARIO2 VAR2-i2-1

Страница 1: ...ed Photocell sensitivity MID Status LEDs ON No PIN Set Unit will change from Programming Mode to Operating Mode after 7 Days or 30 minutes after last press of manual buttons Timer Disabled VARIO2 Spec...

Страница 2: ...plate at the bottom of the unit The number of button pushes indicated below are based on the user starting with the illuminator in either programming or operating mode Action Required Step1 LHS Button...

Страница 3: ...two modes 1 Programming Mode when the remote control can be used and 2 Operating Mode when most of the remote control functions are disabled The only remote control functions that can be used in Oper...

Страница 4: ...rmittent Flashing Red Green Solid Amber to Flashing Red Flash qty counts down the No of characters required After PIN deleted Illuminator goes to Programming Mode Standard LED indication For full PIN...

Страница 5: ...rking Cover photocell fully light should turn on if valid telemetry input It is sometimes difficult to see Infra Red illuminators working in high brightness conditions Ensure power supply is suitably...

Страница 6: ...eam and 120 beam angle ILS Bracketry VARIO2 Enhancements Increased Distance Default time for illuminator to go into Operating Mode reduced PIN function for enhanced security Manual Control added Push...

Страница 7: ...mplete Set up and Installation Step 1 Select different beam angle if required To alter to 10 simply remove interchangeable lens ILS To alter to 60 replace with other ILS lens supplied Other angle ILS...

Страница 8: ...control and buttons are available in Programming Mode The only function of the Remote Control available during Operating Mode is LED Status Indicators Enable Disable entering a PIN or disabling manua...

Страница 9: ...ble manual buttons must be done within 5 minutes of remote disable 9 Extra VRC Functionality PIN Function For extra security VARIO2 allows a PIN Personal Identification Number to be set for each lamp...

Страница 10: ...ough Note invalid characters will not be recognised To create a PIN press STATUS BUTTON for 4 seconds LHS LED will flash RED GREEN This indication will always show that you are in PIN mode RHS LED FLA...

Страница 11: ...gs Power Level Photocell sensitivity Indicator LED status On or Off A continuous 4 second press of the LHS button turns LHS LED flashing RED and enters the user into the Illuminator Security Modes In...

Страница 12: ...e pressed within 2 minutes the Illuminator times out and returns to the previous mode it was in either operating or programming mode 14 Manual Setting Level Indication using RHS Button The RHS BUTTON...

Страница 13: ...Manual Button Control Solid RED Note If the illuminator is in Operating Mode and the buttons are currently disabled you cannot re enable 17 NOTE If no buttons are pressed within 2 minutes the illumin...

Страница 14: ...sed in either Illuminator Settings Modes or Illuminator Configuration Modes the Illuminator will default into Operating Mode 30 minutes after the last button press RESET Options There are Two Re set o...

Страница 15: ...and correctly wired 20 VARIO2 Specifications Table Infra Red Series White Light Series i16 w16 i8 w8 i6 i4 w4 i2 w2 10 500m 1640ft 250m 820ft 350m 1148ft 180m 591ft 200m 656ft 144m 472ft 110m 361ft 78...

Страница 16: ...tion to ensure required distance is achievable Check unit is set to max power Check orientation of unit and ensure it is pointing in correct direction Check angle of unit Interchangeable lens Too narr...

Страница 17: ...10 17 Raytec Global excluding Americas Tel 44 0 1670 520055 Fax 44 0 1670 819760 sales rayteccctv com Americas Tel 1 613 270 9990 Toll Free 1 888 505 8335 ussales rayteccctv com www rayteccctv com Ver...

Отзывы: