Remote Control Operation
PIN set and Manual Button Disable / Enable
Action
Required
Available
Mode
Step1
Step 2
LHS
LED
RHS
LED
Comment
Disable
Remote
Programming
Mode
Press
<Disable
Remote
Control>
button on
VRC for 4
seconds
N/A
Solid Green
Flashing Amber to
Solid Amber to Off
Illuminator will go
to Operating
Mode. RHS LED
turns Off when in
Operating Mode.
Disable
Manual
Buttons
Operating
Mode
Press
<Disable
Remote
Control>
button on
VRC for 4
seconds
N/A
Solid Green –
After 4
seconds
Flashing Red
(Returns to
Solid Green
after button
release)
Off to Solid Amber,
then after 4
seconds Flashing
Red
(Returns to Solid
Green after button
release)
Must be done
within 5 minutes
of Disabling
remote (as
above) Change
will take effect
after 30 minutes
Create or
Change
PIN
Programming
Mode
Press
<Status
Button>
for 4
seconds
Enter
valid PIN
charact
ers
x 4
Green to
Intermittent
Flashing Red /
Green
Solid Amber to
Flashing Red
Flash qty counts
down the No. of
characters
required.
After PIN created
Illuminator goes
to Programming
Mode (Standard
LED indication)
Enter
existing PIN
Operating
Mode
Press
<Status
Button>
for 4
seconds
Enter
valid PIN
charact
er
x 4
Green –
Intermittent
Flashing Red /
Green
Solid Amber to
Flashing Green
Flash qty counts
down the No. of
characters
required
If invalid PIN
entered both
LEDs flash red and
unit will stay in
Operating Mode
Delete PIN Programming
Mode
Press
<Status
Button>
for 4
seconds
Press
<Re-Set>
button 4
times
Green –
Intermittent
Flashing Red /
Green
Solid Amber to
Flashing Red Flash
qty counts down
the No. of
characters
required
After PIN deleted
Illuminator goes
to Programming
Mode (Standard
LED indication)
For full PIN function detail (inc valid PIN characters) – see FULL instruction
guide
LED Status Indicators:
Programming Mode and Operating Mode
On first power up (Factory Default) the illuminator automatically enters
Programming Mode. It will then time out automatically after 7 Days to Operating
Mode unless the user actively disables the remote control or uses the manual
buttons in which case Operating Mode will start 30 minutes after the last manual
button press. The LED Indicators feedback the mode you are in. (They are also
used for PIN or Manual Button Control Modes – please see tables / FULL Instruction
Manual)
During Programming Mode and Operating Mode the two LED’s indicate the
following status :
•
LHS SOLID GREEN:
Power Applied
•
LHS FLASHING GREEN:
Remote control IR received problem
•
RHS FLASHING AMBER:
Indicates unit is in programming mode
(Programming Mode Only)
•
RHS SOLID AMBER:
Indicates that a valid command is being received
(Programming Mode Only)
•
LHS FLASHING RED:
Voltage supply problem detected
•
LHS SOLID RED:
Illuminator LED fault detected
All functions of the remote control and buttons are available in Programming
Mode.
The only function of the Remote Control available during Operating Mode is
LED Status Indicators Enable/Disable, entering a PIN or disabling manual buttons
(if done at the same time as disabling the remote – see FULL Instruction Manual
Left hand side
(LHS) Button
Right hand side
(RHS) Button
Left hand side
(LHS) LED
Right hand side
(RHS) LED