15
Illuminator Settings Mode Detail :
Enter this mode by a momentary press of LHS button to turn LHS LED solid
RED.
Pressing the LHS button again will turn the LED solid GREEN and pressing a
third time will turn the LED solid AMBER. Each of these colours indicates
which setting mode you are in.
A further momentary press of LHS Button will exit from the mode entry,
both LEDs will go out for 1 second and then return to the standard
indication of either operating mode or programming mode (depending
on which mode the Illuminator was in previously before selecting manual
controls.
The following modes are available :
Power Level Mode (LHS LED : Solid RED)
RHS LED :
20% Power Setting: 1 Flash GREEN
40% Power Setting: 2 Flashes GREEN
60% Power Setting: 3 Flashes GREEN
80% Power Setting: 4 Flashes GREEN
100% Power Setting: 5 Flashes GREEN
Photocell Level Mode (LHS LED : Solid GREEN)
RHS LED:
Low sensitivity:
1 Flash GREEN
Medium Sensitivity: 2 Flashes GREEN
High Sensitivity:
3 Flashes GREEN
Disabled photocell: Solid RED
Enable / Disable Status Indicator LEDs Mode (LHS LED: Solid AMBER)
RHS LED:
Enable LEDs: Solid GREEN
Disable LEDS: Solid RED
NOTE – If no buttons are pressed within 2 minutes the Illuminator times out
and returns to the previous mode it was in – either operating or
programming mode.
14
Manual Setting / Level Indication using RHS Button :
The RHS BUTTON will only have an effect if you have selected a mode
using LHS Button – pressing RHS Button without previously pressing LHS
Button will have no effect on the Illuminator operation – it is used to
control the setting for the mode chosen by LHS Button
When you select a mode using LHS BUTTON, the LHS LED will confirm
which mode you are in and RHS LED will show the current setting / level
of that mode for the Illuminator.
Sequential presses of RHS BUTTON will take you through the available
options to get to the required setting you want within that mode. The
Illuminator will stay at this setting / level providing you do not push the
RHS BUTTON again. Once you have reached the required setting as
shown in the following text, EITHER press the LHS BUTTON to cycle through
the modes until LHS LED extinguishes showing that you are at the end of
the mode loop OR you can also wait 2 minutes for the illuminator to time
out and the value shown by RHS LED will be stored into the illuminator
memory.
The settings programmed will be retained on power recycling unless a
reset has been performed, in which case the factory defaults will be
applied.