RESET:
Settings Re-set : Pressing and holding the RESET BUTTON on the remote control
or using the manual buttons to complete a RESET will restore the factory
settings to the illuminator. Note : It will not remove a PIN if one is present.
Full Re-set : Re-cycling the power whilst pressing both manual buttons will
restore factory settings and remove a PIN if one is present.
Both indicator LEDs flash amber for both above re-sets when complete.
VARIO2 Quick Troubleshoot:
Ensure all tests are undertaken by a qualified, trained engineer. Ensure safe
working practices are followed at all times.
•
Check polarity of illuminator connection red=+ve, black=-ve
•
Ensure power is 12-24V AC or DC (For Vario 16 variants : 24V only AC or DC )
•
Ensure telemetry wires are shorted out or valid telemetry input (zero volt or
TTL) is applied and correctly wired
•
Check photocell is working. Cover photocell fully, light should turn on if valid
telemetry input. It is sometimes difficult to see Infra-Red illuminators working in high
brightness conditions.
•
Ensure power supply is suitably rated to product - check page 1 for
specifications
•
If longer cables used, ensure sufficient voltage is provided to allow for drops
across the cable
For in-depth Troubleshoot, see Full Instructions, or contact Ray
/('
.
0DLQ2IILFH
7
)
(PDLOVDOHV#UD\OHGFRP
ZZZUD\OHGFRP
Содержание VARIO 2 VAR2-i8-3
Страница 5: ......
Страница 32: ...0DLQ 2IILFH 7 PDLO VDOHV UD OHG FRP ZZZ UD OHG FRP s...