8
www.raytecled.com
UK / Europe Tel: +44 (0) 1670 520055
Americas Tel: + 1 613 270 9990
Notes
•
The luminaire will switch off momentarily (<0.5sec) during the transition between a
test and normal operation.
If a test was interrupted by a mains failure, the test will be halted, and the unit will
enter emergency mode. Once the mains supply is back, the unit will allow 24 hours
to recharge the battery before continuing the tests.
The self-test is carried out at a random time to eliminate the possibility of having more
than one unit undergoing the test at the same time.
4. Technical Specification
WL84-STD
WL84-EM
WL168-STD
WL168-EM
Input Voltage
110-254V AC
Input Current (230Vac, full load)
0.15A
0.3A
Consumption
24W STD
32W EM
49W STD
56W EM
Power Factor (230Vac, fullload)
>0.95
Mains Frequency
50/60Hz
Inrush Current (I
peak
@50%)
20A, ∆t < 300µs
28A, ∆t < 300µs
Total Harmonic Distortion (230Vac,full load)
< 1 0%
IP Rating
IP66/67
Weight (std)
6Kg
7Kg
9Kg
10Kg
Dimensions
See previous pages for linediagrams
Ambient Range
-40°C to +60°C
-20°C to +50°C (EM versions)