www.raytecled.com
7
UK / Europe Tel: +44 (0) 1670 520055
Americas Tel: + 1 613 270 9990
WARRIOR Intelligent Emergency Operation Guide
The light fitting will carry out the following function
automatically
after installation:
•
Commissioning Cycle
•
Function test
•
Self-test
A tri-colour LED indicator displays the light fitting status. The indication colours are shown in
table 1.
a. Commissioning Cycle
•
Starts automatically after 24 hours of uninterrupted charging
•
3 charge/discharge cycles to optimise battery’s full capacity.
•
Battery is charged for 24 hours before each discharge cycle.
•
No need for manual commissioning
b. Function Test
•
Carried out every 7 days.
•
Checks the function of the battery, lamp and power supply.
•
Lasts for few minutes only.
c. Self-test
•
Carried out at a random time every 3 month.
•
Checks the battery’s capacity and lamp’s condition.
•
Performs self-recovery for the battery if not at peak capacity.
•
Is carried out at 100% load
•
Discharges only 2/3 of the battery’s capacity.
LED indication
LED Indication
Condition
Blinking amber
Commissioning
Static Amber
Function Test
Self-test
Blinking Red
Battery defective/Fuse blown
PSU error
Battery not at peak capacity
Light engine failure
No light
Emergency mode activated
Static Green
Battery charged and PSU OK