background image

- 28 -

(including without limitation of loss of profit, harm to goodwill or business reputation,
or delay damages) arising from or out or the Product or its installation, use,
performance or non-performance, or any defect or breach of warranty, whether
based on contract, warranty, negligence, strict liability, or any other theory.
RAYSTECH’s
aggregate liabilities, if any, in damages or otherwise, shall not exceed the purchase
price paid by the Original Buyer for the product.

2.3 Exclusions of Warranty

Damage or impairment to the Products resulting from any of following activities are
NOT covered by this Warranty:

Installation or use with any devices not approved as compatible by RAYSTECH.
Failure to install or use the battery in the way intended, or as demonstrated in the
installation manual including incorrect-installation of cables and connections.
Failure caused by charger or inverter unit.
Incorrect transportation, storage, installation or wiring by consumer or installer;if
buyer fails to use the original packing materials provided by seller during the
transportation of equipment the products damage or failure shall not fall under the
warranty scope of the product.
Mistreatment of the product including incorrect installation environment, incorrect
temperatures or using the units other than in the specified manner.
Damage caused by any impact, physical trauma to the unit such as dropping or
mishandling.
Attempts to change the functionality of the unit in any way.
exposure of the Product to movement or shaking following installation, or
temperatures of more than 50°C or below -10°C;
Using the battery outside of the clearly stated performance criteria for the unit.
Water ingress, corrosive gas damage or installation in dirty environments causing
particles to affect performance.
Anyone other than those authorized by RAYSTECH may not modify, disassemble,

repair or replace the product;

The unit must have clearly identifiable and authentic serial number and labels on
the unit.
Products suffered any external influences including unusual physical force,
electrical stress (power failure surges,inrush current,lightning,flood,fire,accidental
breakage,etc)
Extensive superficial damage to the case demonstrating impact or mishandling or
poor protection of the battery.
Product damage and defect caused by deliberately or willful act.
Products failure is not reported to seller or RAYSTECH authorized service partner

w within 1 week of appearance.

The Product not being operated for any period of 6 months or more.
Unusual physical or electrical stress caused by

Force majeure

, such as power

Содержание RT-5100S

Страница 1: ...be installed in Parallel more attention should be paid for the DIP and address selection following with part 5 3 2 About this Manual The Manual is intended for theRT 5100S Residential ESS the hybrid i...

Страница 2: ...rap battery 3 1 7 Customer careline 3 2 Product Introduction 3 2 1 Technical data 3 2 2 Exploded views of battery 4 2 3 Indicator and ports 4 2 4 Communication interface plat DVC A2 voltage 5 2 5 How...

Страница 3: ...and Slave battery ies connection 13 5 4 Cable connections 15 5 4 1 Cable connection for Parallel connection 16 5 4 1 1 Ground installation 16 5 4 1 2 Wall mounting 16 6 Configuration 17 6 1 Configure...

Страница 4: ...to a procedure or practice which if not correctly performed or adhered to could result in damage to or destruction of part or all of the RAYSTECH equipment and or other equipment connected to the RAYS...

Страница 5: ...battery pack may catch fire when heated above 130 C If a fire breaks out where the battery is installed do these actions 1 Extinguish the fire before the battery catches fire 2 If the battery has caug...

Страница 6: ...es Knowledge of and adherence to this manual and all safety precautions and best practices 1 6 Scrap battery For scrap battery please treat with local laws or regulations to recycle or scrap 1 7 Custo...

Страница 7: ...CAN RS485 Protection Mode Triple Hardware Protection Battery Protection Over Current Over Voltage Short Circuit Under Voltage Over Temperature Safety Certificate CE TUV IEC 62619 IEC 62040 Hanrzd Cla...

Страница 8: ...t Battery is in a warning state see troubleshooting in Chapter 8 2 4 Communication interface plat DVC A2 voltage SW1 DIP switch select for CAN or RS485 SW2 Resistance for communication and DIP switch...

Страница 9: ...insufficient to meet self consumption requirement electricity will be obtained from the grid 2 6 Features The RAYSTECH Residential ESS has following features Energy storage unit This battery is suit f...

Страница 10: ...y label had been affixed to the shipping carton to alert individuals as to the battery within the package have been disconnected otherwise the battery should not be transported 4 We have conducted com...

Страница 11: ...emperature is outside the operating range battery will protect itself by shutting down The battery optimal operate temperature is 15 C to 30 C Frequent exposure to severe operating condition would exa...

Страница 12: ...the battery pack those following tools are probably required Phillips screwdriver Torque wrench Cable crimper Wire clamp Voltmeter Tape measure Drill Flat head screwdriver In order to protect operato...

Страница 13: ...Do not stack more than 8 battery boxes The temperature of battery stored recommended in the range of 20 C to 25 C Do not expose to water The ESS box should be upright and not stacked upside down when...

Страница 14: ...t 4s and then release it after the two LED lights on measure the voltage at the terminal interface with a voltmeter If the voltage is lower than 48 V do not use the battery and contact RAYSTECH custom...

Страница 15: ...ten the battery to bracket fasten the holes with M6 screws with 2 0N m roughly 4 Meanwhile two or four batteries could be installed by theses brackets Note if more than 4 batteries installed a cabinet...

Страница 16: ...energy needed 2 to 4 batteries could be installed in one stack 3 If the number of batteries at the range of 5 to 8 a cabinet is recommended to be selected 5 3 2 Address selection of Master and Slave...

Страница 17: ...position probably lead serious fault even dangerous Connected battery number Group Set of SW2 Address Set SW3 Parallel connect 1 13 1 2 Master 13 2 Slave 1 1 3 Master 13 3 Slave 1 0 1 Slave 2 1 2 4 M...

Страница 18: ...Slave 1 0 1 Slave 2 0 2 Slave 3 0 3 Slave 4 0 4 Slave 5 0 5 Slave 6 1 6 8 Master 13 8 Slave 1 0 1 Slave 2 0 2 Slave 3 0 3 Slave 4 0 4 Slave 5 0 5 Slave 6 0 6 Slave 7 1 7 5 4 Cable connections WARNING...

Страница 19: ...1 Ground installation For parallel installation please pay attention on Cable connection and the DIP8 of SW2 no need to be changed and stayed on Initial Factory state 5 4 1 2 Wall mounting For wall m...

Страница 20: ...arallel connecting multiple batteries please set the DIP switches as following 6 1 Configure device WIFI The RAYSTECH Residential ESS has a built in WIFI module to use with the RAYSTECH APP The WIFI s...

Страница 21: ...ata in real time Data query Support users to view the current voltage temperature and other operating data of the bound battery support to view any 24 hour battery operation data in the data record su...

Страница 22: ...nstallation package to complete you can open it for use 2 IOS installation Open IOS s own application store Search for Smart BESS in the APP Store Enter the Smart BESS application details page click G...

Страница 23: ...k and then click the Done button to complete the registration 6 2 2 2 User Login After successful registration it will automatically return to the login page enter the registered user name and passwor...

Страница 24: ...ery device and this item is obtained automatically after clicking Start the APP will automatically connect to the battery for battery distribution network operation and return to the main page after c...

Страница 25: ...ed in the Battery List Status TEMP Voltage and Current information are displayed in the single battery list and Online Offline shows that the current battery is offline Click Detail to view the detail...

Страница 26: ...ty if there is a problem that cannot be solved you can also contact the local supplier to solve it 6 2 2 8 Other Functions User password modification Click Reset Password on the login page to enter th...

Страница 27: ...stalled use the following steps to put it in operation 1 Press and hold the panel button on the left side of the unit for about 4s after the indicator lights on release the panel button 2 Make sure th...

Страница 28: ...tery fault light is on please check the Fault code in Homepage 2 If the battery fault light on please check the Troubleshooting number in Homepage in your RAYSTECH APP if the code is 0x1 this problem...

Страница 29: ...er voltage and cell over charge protection 0x2005 Battery under temperature protection 0x2006 Battery over temperature protection 0x2007 Battery charge over current protection 0x2008 Battery discharge...

Страница 30: ...the date of manufacturing whichever comes first This Warranty period covers a capacity equivalent to 1 full cycle per day Full cycle Discharge the nominal capacity of a fully charged battery and fully...

Страница 31: ...uct including incorrect installation environment incorrect temperatures or using the units other than in the specified manner Damage caused by any impact physical trauma to the unit such as dropping o...

Страница 32: ...to be valid in which case RAYSTECH will be responsible for the testing costs 4 Warranty Policy If on arrival the product is not of acceptable quality the customer is entitled to have the goods repaire...

Страница 33: ...t and would credit the cost of returning the unit to us for testing based on standard acceptable logistical costs 7 Out Of Warranty In the event the Product is out of warranty RAYSTECH may in its disc...

Страница 34: ...onformity with the essential requirements and other relevant requirements of the RED Directive 2014 53 EU The product is in conformity with the following standards and or other normative documents HEA...

Отзывы: