Parameter
Value Range
Description
Temp. Units
Celsius/Fahrenheit
Temperature units
IDU Baud Rate
1200 - 460800
Specifies the baud rate on S.Port 2 (PC
interface). The value is stored
permanently and is not reset at power-up.
LED Mode
Normal/Stealth
Enables (Normal) or Disables (Stealth) the
ACU LEDs
Antenna Configuration
This page configures the available band details of the currently installed LNB, and
makes this information accessible to the Satellite page where the current active band
can be selected from the bands available to the antenna.
The values in the Antenna Configuration page are generally only set
at the factory according to the LNB ordered with the antenna, or if
the LNB is replaced. Any changes to this page should be performed
only under Gilat supervision.
Figure 58: Antenna Configuration page
Table 18: ACU web interface - Antenna Configuration parameters
Parameter
Value Range
Description
LNB LO,
(MHz)
BDC local oscillator (LO) frequency.
Value ranges and entries depend on the LNB type and
manufacturer.
For antenna with single-band LNB:
Low sub-bands:
For 10950-11200 MHz range, enter LNB LO = 10000 MHz
For 11200-11700 MHz range, enter LNB LO = 10250 MHz
High band:
For 11700-12750 MHz, enter LNB LO = 10750 MHz.
(or 11300 MHz, leading to a reduced operational frequency
band 12250-12750 MHz)