5
2. BEFORE INSTALLATION
Raypak strongly recommends that this manual be re-
viewed thoroughly before installing your XFiire heater.
Please review the General Safety information before
installing the heater. Factory warranty does not apply to
heaters that have been improperly installed or operated.
Refer to the warranty at the back of this manual.
Installation and service must be performed by a qualified
installer, service agency, or gas supplier. If, after reviewing
this manual, you still have questions which this manual
does not answer, please contact your local Raypak
representative or visit our website at www.raypak.com.
NOTE:
Raypak recommends laying out and installing
the vent system before installing water piping. This
will ensure that the venting system and associated
components will fit into the attached space for proper
operation.
Thank you for purchasing a Raypak product. We hope you
will be satisfied with the high quality and durability of our
equipment.
Product Receipt
On receipt of your heater it is suggested that you visually
check for external damage to the shipping crate. If the
crate is damaged, make a note to that effect on the Bill of
Lading when signing for the shipment. Next, remove the
heater from the shipping packaging. Report any damage
to the carrier immediately. On occasion, items are shipped
loose. Be sure that you receive the correct number of
packages as indicated on the Bill of Lading.
Claims for shortages and damages must be filed with the
carrier by consignee. Permission to return goods must
be received from the factory prior to shipping. Goods
returned to the factory without an authorized Returned
Goods Receipt number will not be accepted. All returned
goods are subject to a restocking charge.
When ordering parts, you must specify the model and
serial number of the heater. When ordering under warranty
conditions, you must also specify the date of installation.
Purchased parts are subject to replacement only under the
manufacturer’s warranty. Debits for defective replacement
parts will not be accepted. Parts will be replaced in kind
only per Raypak’s standard warranties.
Model Identification
The model identification number and heater serial number
are found on the rating plate located on the rear jacket
panel of the heater. See
Figure 3
.
The model number will have the form H7-1000B* or similar
depending on the heater size and configuration.
•
The letter(s) in the first group of characters identifies
the application (H = Hydronic Heating, WH = Water
Heating).
•
The number which follows identifies the firing mode
(7 = electronic modulation).
•
The second group of characters identifies the size
of the heater (the four numbers representing the
approximate MBTUH input), and, where applicable, a
letter, indicating the manufacturing series.
Ratings and Certifications
Standards
• ANSI Z21.13 · CSA 4.9 - latest edition, Gas-Fired Hot
Boilers
• ANSI Z21.10.3 CSA 4.3- latest edition, Gas Water
Heater
• CAN 3.1 - latest edition, Industrial and Commercial
Gas-Fired Package Heaters
All Raypak heaters are National Board registered, and
design-certified and tested by the Canadian Standards
Association (CSA) for the U.S. and Canada. Each
heater is constructed in accordance with Section IV of
the American Society of Mechanical Engineers (ASME)
Heater Pressure Vessel Code and bears the ASME "H"
stamp. This heater also complies with the latest edition of
the ASHRAE 90.1 Standard.
A
A
WARNING:
Altering any Raypak pressure vessel by
installing replacement heat exchangers, or any ASME
parts not manufactured and/or approved by Raypak will
instantly void the ASME and CSA ratings of the vessel
and any Raypak warranty on the vessel. Altering the
ASME or CSA ratings of the vessel also violates national,
state, and local approval codes.
Installations at Elevation
Rated inputs are suitable for up to 4,500 ft (1,372 m)
elevation. Consult your local representative or the
factory for installations at altitudes over 4,500 ft (1,372
m) above sea level. No hardware changes are required
to the heaters for installations up to 10,000 ft (3,050 m)
(adjustments may be required).
General Information
Model
No.
Input
MBTUH
Vent Size
in. (mm)
Max
Min
Flue
Intake
300B
300
42.8
4 (100)
4 (100)
400B
399
57.1
4 (100)
4 (100)
500B
500
71.4
4 (100)
4 (100)
650B
650
92.8
6 (150)
6 (150)
800B
800
114.2
6 (150)
6 (150)
1000B
1000
142.8
6 (150)
6 (150)
Table A. Basic Product Data
Содержание Xfiire 300B
Страница 54: ...54 6 WIRING DIAGRAM For a full size drawing visit www raypak com...
Страница 70: ...70 NOTES...
Страница 71: ...71 NOTES...