23
Check the Power Source
A
WARNING:
Using a multi-meter, check the following
voltages at the circuit breaker panel prior to connecting
any equipment. Make sure proper polarity is followed
and house ground is proven.
Check the power source:
• AC = 104VAC Minimum, 126VAC MAX
• AB = 208VAC Minimum, 252VAC MAX
• BC = 104VAC Minimum, 126VAC MAX
CIRCUIT
BREAKER
WHITE
HOT (L2)
GROUND
BLACK
HOT (L1)
GREEN
A B C
Figure 22. Wiring Connections
Figure 23.
Multi-meter
Injector Pump Wiring
The 3-phase cold water run pump is shipped loose and
must be field wired.
Before Starting
1. Turn off power to the unit at the circuit breaker.
2. Turn off gas supply.
3. Shut-off the water supply to the heater and, if
necessary, drain water from the system.
4. Locate the pump junction box and wiring decal shown
in
Figure 24
.
5. Remove the pump junction box cover shown in
Figure 24
and locate the 9 wires inside.
DECAL
COVER
Figure 24. Pump Wiring Decal and Junction Box
6. Wire in accordance with the low-voltage (230VAC)
decal located next to the pump junction box (do not
connect high-voltage 460 volt power to the control
box).
7. In the absence of the pump-mounted decal, use
Table
F
to complete the wiring between the cold water run
control box and the 3-phase injector pump. Use wire
nuts (field supplied) to complete these connections
and ensure that all connections are tight.
230VAC 3 ø Line
Low Voltage Pump Wiring
Black
Orange (3) and Gray (9)
Red
Red (8) and White (2)
White
Pink (7) and Blue (1)
———————
Yellow (4) and Black (5) and Violet
(6)
Green
Ground Lug
Table F. Cold Water Run Control Panel and Injector Pump
Wiring
8. Re-install the injector pump junction box cover.
9. Turn on the water and gas supply.
10. Turn the electrical supply on to the heater and to the
cold water run system.
Содержание Raypak Delta Limited WH1-399B
Страница 14: ...14 Wiring Diagrams Cold Water Start ...
Страница 19: ...19 CWS CONTROL BOX ASSY SEE PAGE 16 FOR HEATER INTERFACE WIRING SEE PAGE 17 Wiring Diagram Multiple Boiler ...
Страница 29: ...29 Wiring Diagrams Cold Water Run SEE PAGE 17 ...
Страница 31: ...31 7 ILLUSTRATED PARTS LISTS Cold Water Start Manufactured from 2006 through current ...
Страница 32: ...32 1 M 8 M Cold Water Start ...
Страница 33: ...33 Cold Water Start Multiple Boiler Interlock ...
Страница 34: ...34 NOTE Sizing is specific to the application ...
Страница 36: ...36 9 M 4 M RAYTHERM MODELS 2100 4001 ONLY 1 H 5 M 6 M 7 M 8 M 10 M 12 M 11 M 4 M 2 M 1 M Cold Water Run ...
Страница 37: ...37 NOTE Sizing is specific to the application ...
Страница 38: ...38 NOTES ...
Страница 39: ...39 NOTES ...