Raynor Commander II Safety Signal 3240RGD Скачать руководство пользователя страница 8

8

Installation Step 1

Determine the Header Bracket Location

Installation procedures vary according to garage door types. 
Follow the instructions which apply to your door.

Close the door and mark the inside vertical centerline of the 

1. 

garage door.

Extend the line onto the header wall above the door.

2. 

You can fasten the header bracket within 4 feet
(1.22 m) of the left or right of the door center only if a 
torsion spring or center bearing plate is in the way; or you 
can attach it to the ceiling (see page 9) when clearance is 
minimal. (It may be mounted on the wall upside down if 
necessary, to gain approximately 1/2" (1 cm).

If you need to install the header bracket on a 2x4 (on wall or 
ceiling), use lag screws (not provided) to securely fasten the 
2x4 to structural supports as shown here and on page 8.

Open your door to the highest point of travel as shown. Draw 

3. 

an inter secting horizontal line on the header wall above the 
high point:

3" (7.5 cm) above the high point for sectional door and one-

• 

piece door with track.

8" (20 cm) above the high point for one-piece door without 

• 

track.

This height will provide travel clearance for the top edge of the 
door.

NOTE:

 If the total number of inches exceeds the height 

available in your garage, use the maximum height possible, or 
refer to page 9 for ceiling installation.

To prevent possible serious injury or death:

Header bracket 

• 

MUST be RIGIDLY fastened to structural 

support on header wall or ceiling, otherwise garage door 
might not reverse when required. DO NOT install header 
bracket over drywall.
Concrete anchors 

• 

MUST be used if mounting header bracket 

or 2x4 into masonry.
NEVER

• 

 try to loosen, move or adjust garage door, springs, 

cables, pulleys, brackets, or their hardware, ALL of which 
are under EXTREME tension. 
ALWAYS

• 

 call a trained door systems technician if garage 

door binds, sticks, or is out of balance. An unbalanced 
garage door might not reverse when required.

Header Wall

Sectional door with curved track

Highest Point
of Travel

Door

Track

3" (7.5 cm)

One-piece door with horizontal track

Door

Track

Header Wall

Highest Point
of Travel

3" (7.5 cm)

Header Wall

Vertical Centerline
of Garage Door

Level
(optional)

2x4

2x4

Structural
Supports

OPTIONAL
CEILING
MOUNT
FOR
HEADER
BRACKET

Unfinished
Ceiling

Door

Jamb
Hardware

One-piece door without track: 
jamb hardware

8" (20 cm)

Highest 
Point
of Travel

Door

Pivot

8" (20 cm)

One-piece door without track: 
pivot hardware

Highest 
Point
of Travel

Header Wall

Header Wall

Содержание Commander II Safety Signal 3240RGD

Страница 1: ...the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless the Protector System is connected and properly aligned Periodic checks...

Страница 2: ...r 28 Having a problem 29 Diagnostic chart 30 PROGRAMMING 31 32 To add or reprogram a hand held remote control 31 To erase all codes 31 3 Button remotes 31 To add reprogram or change a Keyless Entry PI...

Страница 3: ...lement Preparing your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or...

Страница 4: ...must not exceed 1 4 6 mm FINISHED CEILING Torsion Spring Access Door Motor Unit Wall mounted Door Control Rail Extension Spring OR Vertical Centerline of Garage Door Sectional Door Installation Planni...

Страница 5: ...kaged in two cartons which contain the motor unit and all parts illustrated below Accessories will depend on the model purchased If anything is missing carefully check the packing material Parts may b...

Страница 6: ...it as shown Slip the coupling over the rail sprocket Slide the rail through the motor unit bracket until the coupling fits securely over the motor unit sprocket Align the two bolt holes in the rail wi...

Страница 7: ...ve 6 floor NEVER 7 connect garage door opener to power source until instructed to do so NEVER 8 wear watches rings or loose clothing while installing or servicing opener They could be caught in garage...

Страница 8: ...the top edge of the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 9 for ceiling installation To prevent possible...

Страница 9: ...P CEILING MOUNT ONLY Wall Mounting Holes Optional Wall Mounting Holes The nail hole is for positioning only You must use lag screws to mount the header bracket UP CEILING MOUNT ONLY Door Spring Header...

Страница 10: ...ely on a temporary support to allow the rail to clear the spring Position the rail bracket against the header bracket Align the bracket holes and join with a clevis pin as shown Insert a ring fastener...

Страница 11: ...e designed to clip onto the track of sectional garage doors without additional hardware If it is necessary to mount the units on the wall the brackets must be securely fastened to a solid surface such...

Страница 12: ...ie flush with the lip hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figures 2 3 Pl...

Страница 13: ...t on each sensor Use wing nuts to fasten sensors to brackets with lenses pointing toward each other across the door Be sure the lens is not obstructed by a bracket extension Figure 5 Finger tighten th...

Страница 14: ...id flat is convenient for setting an ideal door to rail distance Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way and plac...

Страница 15: ...ine 6 with the header bracket if the bracket is not centered above the door Remove the 2x4 Operate the door manually If the door hits 7 the rail raise the header bracket NOTE DO NOT connect power to o...

Страница 16: ...of door control by color white wire to 2 and white red wire to the 1 Figure 3 Remove white cover by gently prying at slot in top of the cover 2 with a small flat head screwdriver Fasten with 6ABx1 1...

Страница 17: ...nd of the rope through the hole in the release arm of the outer trolley Adjust rope length so the handle is 6 feet 1 83 m above the floor Secure with an overhand knot NOTE If it is necessary to cut th...

Страница 18: ...e Black Wire PERMANENT WIRING CONNECTION White Wire Black Wire Installation Step 11 Complete Safety Reversing Sensor Installation ALIGNING THE SAFETY REVERSING SENSORS Plug in the opener The indicator...

Страница 19: ...etween the door panel support and the door bracket Drill 3 16 fastening holes Secure the door bracket using the two 1 4 14x5 8 self threading screws Figure 2A Alternately use two 5 16 bolts lock washe...

Страница 20: ...INUM STEEL DOORS WITH GLASS PANEL ETC NOT PROVIDED One Piece Doors Please read and comply with the warnings and reinforcement instructions on the previous page They apply to one piece doors also Cente...

Страница 21: ...ion with a ring fastener Fasten curved section to the door bracket in the same way using the 5 16 x1 1 4 clevis pin Figure 2 Bring arm sections together Find two pairs of holes that line up and join s...

Страница 22: ...t the limit further One full turn equals 2 5 cm of trolley travel Closed door adjustment decrease DOWN travel limit Turn the DOWN limit adjustment screw clockwise 4 complete turns Nuts 5 16 18 Lock Wa...

Страница 23: ...UP open force as explained in Adjustment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If do...

Страница 24: ...ontrol clockwise Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum amount...

Страница 25: ...r reverses on the 1 1 2 3 8 cm board remove the obstruction and run the opener through 3 or 4 complete travel cycles to test adjustment IMPORTANT SAFETY CHECK Test the Safety Reverse System after Each...

Страница 26: ...size is A19 Bulb power is 100 watts maximum Light feature Lights will also turn on when someone walks through the open garage door With a Multi Function Door Control this feature may be turned off as...

Страница 27: ...for 4 1 2 minutes Press again to turn it off sooner The 4 1 2 minute interval can be changed to 1 1 2 2 1 2 or 3 1 2 minutes as follows Press and hold the Lock button until the light blinks about 10...

Страница 28: ...KG NOTICE To comply with FCC and or Industry Canada IC rules adjustment or modifications of this receiver and or transmitter are prohibited except for changing the code setting or replacing the batte...

Страница 29: ...rce or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Manually check door for balance or any bindin...

Страница 30: ...dim or flashing Realign receiving eye sensor clean lens and secure brackets Verify door track is firmly secured to wall and does not move Symptom Motor has over heated the motor unit does not operate...

Страница 31: ...arn button on 1 the motor unit The learn indicator light will glow steadily for 30 seconds Within 30 seconds press and hold the 2 button on the hand held remote that you wish to operate your garage do...

Страница 32: ...after it has expired To set a temporary PIN Press the four buttons for your personal entry PIN not the last 1 temporary PIN then press and hold the button The opener light will blink three times Rele...

Страница 33: ...g and sending eyes 9 with 3 9 m 2 conductor bell wire attached 41A5266 1 Safety sensor bracket 10 41B4494 1 2 Conductor bell wire white white red 11 178B35 Curved door arm section 12 NOT SHOWN 41A4675...

Страница 34: ...crews 5 41D4671 Limit switch assembly 6 41A6241 Motor drive assy complete 6a 20B21 1 Drive belt 7 41C4672 Screw drive RPM kit KEY PART NO NO DESCRIPTION 8 41A4837 1 Worm gear and retainer 9 41A6635 Lo...

Страница 35: ...nel for a neat compact appearance Enhanced functions include Lock Feature to lock out outside radio signals while you are away from home and turn opener lights on or off from the control panel Garage...

Страница 36: ...DAMAGE DAMAGE CAUSED BY IMPROPER INSTAL LATION OPERATION OR CARE INCLUDING BUT NOT LIMITED TO ABUSE MISUSE FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTE NANCE UNAUTHORIZED REPAIRS OR ANY ALTERATI...

Отзывы: