Raynor Commander II Safety Signal 3240RGD Скачать руководство пользователя страница 16

16

KG

1

3

9

7

5

KG

1

3

9

7

5

To release or insert wire,
push in tab with screwdriver tip

Door Control
Connections

Red

Grey

White

Strip wire 7/16" (11 mm)

7/16" (11 mm)

Figure 2

To Replace
Insert Bottom Tabs First

PRE-WIRED 
INSTALLATION

24 Volt
Bell Wire

LOCK

LIGHT

LOCK

LIGHT

To Replace
Insert Bottom Tabs First

Figure 1

STANDARD 
INSTALLATION

Figure 3

Figure 1

To prevent possible SERIOUS INJURY or DEATH from 
electrocution:

Be sure power is not connected BEFORE installing door 

• 

control.
Connect ONLY to 24 VOLT low voltage wires. 

• 

To prevent possible SERIOUS INJURY OR DEATH from a 
closing garage door:

Install door control within sight of garage door, out of reach 

• 

of children at a minimum height of 5 feet (1.5 m), and away 
from ALL moving parts of door.
NEVER permit children to operate or play with door control 

• 

push buttons or remote control transmitters.
Activate door ONLY when it can be seen clearly, is properly 

• 

adjusted, and there are no obstructions to door travel.
ALWAYS keep garage door in sight until completely closed. 

• 

NEVER permit anyone to cross path of closing garage door.

Figure 4

Figure 2

Drywall
Anchors

Insulated
Staples 

Multi-function (std installation)
6AB x 1-1/4" Screw

Multi-function (pre-wired)
6-32 x 1" Screw

HARDWARE SHOWN ACTUAL SIZE

 Bell Wire

Terminal 
Screws

 Bottom Mounting Hole

 Top Mounting Hole

Installation Step 7

Install the Door Control

Locate door control within sight of the door at a minimum height 
of 5 feet (1.5 m) where small children cannot reach, and away 
from moving parts of the door and door hardware. The 
installation surface must be smooth and flat. If installing into 
drywall (Figure 1), drill 5/32" holes and use anchors provided. For 
pre-wired installations (as in new home construction), it may be 
mounted to a single gang box (Figure 2). 

NOTE:

 After installation, 

a green indicator light behind the cover will indicate proper 
connection. If not lit, the Lock and Light features will not function 
(reverse wires to correct).

Strip 7/16" (11 mm) of insulation from one end of bell wire and 

1. 

connect to the two screw terminals on back of door control by 
color: white wire to 2 and white/red wire to the 1 (Figure 3).

Remove white cover by gently prying at slot in top of the cover 

2. 

with a small flat head screwdriver. Fasten with 6ABx1-1/4" self-
threading screws (drywall installation) or 6-32x1" machine 
screws (into gang box) as follows:

Drill and install bottom screw, allowing 1/8" (3 mm) to 

• 

protrude above wall surface.

Position bottom of door control on screw head and slide 

• 

down to secure. Adjust screw for snug fit.

Install top screw with care to avoid cracking plastic housing. 

• 

Do not overtighten.

Insert bottom tabs and snap on cover.

• 

NOTE:

 The push bar may stick if the door control is not mounted 

on a smooth surface. If a click is not heard when pressing the 
push bar, loosen the two mounting screws or relocate the door 
control to a smoother surface.

(Standard installation only)

3. 

 Run bell wire up wall and across 

ceiling to motor unit. Use insulated staples to secure wire in 
several places. Do not pierce wire with a staple, creating a 
short or open circuit. If your access door is near the garage 
door, you may run this wire with the Safety Reversing Sensor 
wires along the top of the rail. See page 13.

Insert all wires through the opening on top of motor unit above 

4. 

the terminal block on the back panel (Figure 4).

Strip 7/16" (11 mm) of insulation from each set of wires. Insert 

5. 

door control wire into quick-connect terminals by color: white 
wire to white, white/red wire to red.

Separate white and white/black wires sufficiently to connect to 
the opener quick-connect terminals. Twist like colored wires 
together. Insert wires into quick-connect holes: white to white 
and white/black to grey (Figure 4).

NOTE:

 When connecting multiple door controls to the opener, 

twist same color wires together. Insert wires into quick-connect 
holes: white to white and red/white to red.

Use tacks or staples to permanently attach entrapment warning 

6. 

label to wall near door control, and manual release/safety 
reverse test label in a prominent location on inside of garage 
door.

NOTE:

 DO NOT connect the power and operate the opener at this 

time. The trolley will travel to the full open position but will not 
return to the close position until the sensor beam is connected 
and properly aligned. See Step 11 on page 18.

Содержание Commander II Safety Signal 3240RGD

Страница 1: ...the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless the Protector System is connected and properly aligned Periodic checks...

Страница 2: ...r 28 Having a problem 29 Diagnostic chart 30 PROGRAMMING 31 32 To add or reprogram a hand held remote control 31 To erase all codes 31 3 Button remotes 31 To add reprogram or change a Keyless Entry PI...

Страница 3: ...lement Preparing your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or...

Страница 4: ...must not exceed 1 4 6 mm FINISHED CEILING Torsion Spring Access Door Motor Unit Wall mounted Door Control Rail Extension Spring OR Vertical Centerline of Garage Door Sectional Door Installation Planni...

Страница 5: ...kaged in two cartons which contain the motor unit and all parts illustrated below Accessories will depend on the model purchased If anything is missing carefully check the packing material Parts may b...

Страница 6: ...it as shown Slip the coupling over the rail sprocket Slide the rail through the motor unit bracket until the coupling fits securely over the motor unit sprocket Align the two bolt holes in the rail wi...

Страница 7: ...ve 6 floor NEVER 7 connect garage door opener to power source until instructed to do so NEVER 8 wear watches rings or loose clothing while installing or servicing opener They could be caught in garage...

Страница 8: ...the top edge of the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 9 for ceiling installation To prevent possible...

Страница 9: ...P CEILING MOUNT ONLY Wall Mounting Holes Optional Wall Mounting Holes The nail hole is for positioning only You must use lag screws to mount the header bracket UP CEILING MOUNT ONLY Door Spring Header...

Страница 10: ...ely on a temporary support to allow the rail to clear the spring Position the rail bracket against the header bracket Align the bracket holes and join with a clevis pin as shown Insert a ring fastener...

Страница 11: ...e designed to clip onto the track of sectional garage doors without additional hardware If it is necessary to mount the units on the wall the brackets must be securely fastened to a solid surface such...

Страница 12: ...ie flush with the lip hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figures 2 3 Pl...

Страница 13: ...t on each sensor Use wing nuts to fasten sensors to brackets with lenses pointing toward each other across the door Be sure the lens is not obstructed by a bracket extension Figure 5 Finger tighten th...

Страница 14: ...id flat is convenient for setting an ideal door to rail distance Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way and plac...

Страница 15: ...ine 6 with the header bracket if the bracket is not centered above the door Remove the 2x4 Operate the door manually If the door hits 7 the rail raise the header bracket NOTE DO NOT connect power to o...

Страница 16: ...of door control by color white wire to 2 and white red wire to the 1 Figure 3 Remove white cover by gently prying at slot in top of the cover 2 with a small flat head screwdriver Fasten with 6ABx1 1...

Страница 17: ...nd of the rope through the hole in the release arm of the outer trolley Adjust rope length so the handle is 6 feet 1 83 m above the floor Secure with an overhand knot NOTE If it is necessary to cut th...

Страница 18: ...e Black Wire PERMANENT WIRING CONNECTION White Wire Black Wire Installation Step 11 Complete Safety Reversing Sensor Installation ALIGNING THE SAFETY REVERSING SENSORS Plug in the opener The indicator...

Страница 19: ...etween the door panel support and the door bracket Drill 3 16 fastening holes Secure the door bracket using the two 1 4 14x5 8 self threading screws Figure 2A Alternately use two 5 16 bolts lock washe...

Страница 20: ...INUM STEEL DOORS WITH GLASS PANEL ETC NOT PROVIDED One Piece Doors Please read and comply with the warnings and reinforcement instructions on the previous page They apply to one piece doors also Cente...

Страница 21: ...ion with a ring fastener Fasten curved section to the door bracket in the same way using the 5 16 x1 1 4 clevis pin Figure 2 Bring arm sections together Find two pairs of holes that line up and join s...

Страница 22: ...t the limit further One full turn equals 2 5 cm of trolley travel Closed door adjustment decrease DOWN travel limit Turn the DOWN limit adjustment screw clockwise 4 complete turns Nuts 5 16 18 Lock Wa...

Страница 23: ...UP open force as explained in Adjustment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If do...

Страница 24: ...ontrol clockwise Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum amount...

Страница 25: ...r reverses on the 1 1 2 3 8 cm board remove the obstruction and run the opener through 3 or 4 complete travel cycles to test adjustment IMPORTANT SAFETY CHECK Test the Safety Reverse System after Each...

Страница 26: ...size is A19 Bulb power is 100 watts maximum Light feature Lights will also turn on when someone walks through the open garage door With a Multi Function Door Control this feature may be turned off as...

Страница 27: ...for 4 1 2 minutes Press again to turn it off sooner The 4 1 2 minute interval can be changed to 1 1 2 2 1 2 or 3 1 2 minutes as follows Press and hold the Lock button until the light blinks about 10...

Страница 28: ...KG NOTICE To comply with FCC and or Industry Canada IC rules adjustment or modifications of this receiver and or transmitter are prohibited except for changing the code setting or replacing the batte...

Страница 29: ...rce or travel limits The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Manually check door for balance or any bindin...

Страница 30: ...dim or flashing Realign receiving eye sensor clean lens and secure brackets Verify door track is firmly secured to wall and does not move Symptom Motor has over heated the motor unit does not operate...

Страница 31: ...arn button on 1 the motor unit The learn indicator light will glow steadily for 30 seconds Within 30 seconds press and hold the 2 button on the hand held remote that you wish to operate your garage do...

Страница 32: ...after it has expired To set a temporary PIN Press the four buttons for your personal entry PIN not the last 1 temporary PIN then press and hold the button The opener light will blink three times Rele...

Страница 33: ...g and sending eyes 9 with 3 9 m 2 conductor bell wire attached 41A5266 1 Safety sensor bracket 10 41B4494 1 2 Conductor bell wire white white red 11 178B35 Curved door arm section 12 NOT SHOWN 41A4675...

Страница 34: ...crews 5 41D4671 Limit switch assembly 6 41A6241 Motor drive assy complete 6a 20B21 1 Drive belt 7 41C4672 Screw drive RPM kit KEY PART NO NO DESCRIPTION 8 41A4837 1 Worm gear and retainer 9 41A6635 Lo...

Страница 35: ...nel for a neat compact appearance Enhanced functions include Lock Feature to lock out outside radio signals while you are away from home and turn opener lights on or off from the control panel Garage...

Страница 36: ...DAMAGE DAMAGE CAUSED BY IMPROPER INSTAL LATION OPERATION OR CARE INCLUDING BUT NOT LIMITED TO ABUSE MISUSE FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTE NANCE UNAUTHORIZED REPAIRS OR ANY ALTERATI...

Отзывы: