function. Make sure the control valve is returned to the service position. 11. Replace the control
valve back cover. Set top leading edge of cover over the 2 legs and rotate down 12. Make sure there is
enough brine in the brine tank.13. Plug cable into meter cover. 14. Press the Extra Cycle button to
allow the unit to regenerate that evening.
To Remove and Replace Motor 1. Follow steps Al through A4. 2. Remove the clear Motor Bearing on the
front face of the powerhead by turning clockwise. 3. Disconnect wire nuts on motor leads and
powercord. 4. Remove the two screws holding motor in place and pull motor out of powerhead.
Note:You may have to rock motor slightly to theside. 5. Place new motor in position. Motor
should setflush with powerhead and install the two screws.6. Reconnect motor leads and powercord
and installwire nuts. Note: Motor leads should be wrapped clockwise around the motor coil to
keep clear of the mechanical operation of the
Control Valve.
Install the clear Motor Bearing on the front face of the powerhead. B. To Replace or Clean Injectors and
Screen 1. Follow steps Al through A3. 2. Remove the two screws in the injector cap. Remove injector cap
and discard seal. With screwdriver, pry injector nozzle and throat assembly from valve body. 3. Push in
cleaned or new injector nozzle and throat assembly. Be sure they are all the way in. Clean or install a
new screen. 4. Install new Injector cap seal in Valve Body. 5. Insert screws through injector cap into
mating 6. holes in the valve body and tighten screws. 7. Return by pass or inlet valving to normal service
position. Water pressure should now be applied to the conditioner and any by pass line shut off. Check
for leaks at seal around injector cap. C. To Replace Piston and/or Seals and Spacers and/or Brine Valve
Follow steps A1 through A.5. Remove the three screws and pull upward on end plug and piston
assembly to remove it from
Valve Body.
To Replace Brine Valve a. Pull brine valve from valve body, also remove
and discard o ring at bottom of brine valve hole b. Apply silicone lubricant to new o ring andreinstall at
bottom of brine valve hole. c. Apply silicone lubricant to new o ring on new brine valve assembly and
press into place, shoulder on bushing should be flush with valve body. 4. To Replace Seals and Spacers:
a. Remove seals and spacers using your fingers from valve body. b. Inspect the inside bore of the valve
for foreign matter that could interfere with valve operation. c. Replace new seals and spacers using your
fingers to set in place. 5. To Replace Piston: a. Inspect the inside of the valve to make sure that all seals
and spacers are in place, and that there is no foreign matter that could interfere with valve operation.b.
Take new piston and end plug assembly as furnished and push piston into valve by means of the end
plug.6. Install and tighten the three screws in the end plug.7. Return by pass or inlet valve to normal
service position. Water pressure should now be applied to the conditioner and any by pass line shut off.
Check for leaks at all seal areas. 9. Follow steps A6 through A14. E. To Replace Meter
Turn off water supply to conditioner: a. If the conditioner installation has a “three valve” by pass system,
first open the valve in the by-pass line, then close the valves at the condi-tioner inlet and outlet. b. If the
conditioner has an integral by pass valve, put it in the by pass position. c. If there is only a shut off valve