30
ST60+ Depth Instrument Owner’s Handbook
Shallow alarm lock
When set to
On
, the shallow alarm lock prevents inadvertent alteration to the
shallow depth alarm setting.
Note:
The procedure for setting alarm level levels is given in Chapter 1, Operation.
Pop-up pilot
Switches the pop-up pilot function on and off.
Leaving User calibration
Hold down the
depth
and
alarm
buttons for 2 seconds to save your settings, exit
User calibration and resume normal operation.
4.3 Intermediate calibration
Intermediate calibration enables you to:
• Check the instrument software version.
• Set the instrument status - either
MASTER
or
REPEATER
.
To access the Intermediate calibration screens, hold down the
depth
and
alarm
buttons for approximately 4 seconds. the software version screen is displayed.
To set the instrument status:
1. Press the
depth
button to select the Instrument status screen.
2. Press the
offset
and
reset
buttons simultaneously to enter adjust mode,
then press either
offset
or
reset
to
set the required status.
Note:
You must not allocate more than one MASTER depth instrument in any system.
Intermediate calibration
Software
version
Instrument
status
Hold down
for approximately 4 seconds
depth
alarm
+
(or REPEATER)
depth
depth
D8166-1
81262_2.book Page 30 Friday, November 11, 2005 11:11 AM
Содержание ST60+ SPEED INSTRUMENT
Страница 8: ...vi ST60 Depth Instrument Owner s Handbook 81262_2 book Page vi Friday November 11 2005 11 11 AM...
Страница 18: ...6 ST60 Depth Instrument Owner s Handbook 81262_2 book Page 6 Friday November 11 2005 11 11 AM...
Страница 22: ...10 ST60 Depth Instrument Owner s Handbook 81262_2 book Page 10 Friday November 11 2005 11 11 AM...
Страница 38: ...26 ST60 Depth Instrument Owner s Handbook 81262_2 book Page 26 Friday November 11 2005 11 11 AM...
Страница 46: ...34 ST60 Depth Instrument Owner s Handbook 81262_2 book Page 34 Friday November 11 2005 11 11 AM...
Страница 50: ...38 ST60 Depth Instrument Owner s Handbook 81262_2 book Page 38 Friday November 11 2005 11 11 AM...
Страница 52: ...81262_2 book Page 40 Friday November 11 2005 11 11 AM...
Страница 54: ...81262_2 book Page 42 Friday November 11 2005 11 11 AM...