Chapter 3: Installation
13
• Be as near as possible to the center line of the vessel.
• Be clear of other through-hull fittings or projections.
• Have sufficient clearance inside the hull to fit the nut.
• Have 4 in (100 mm) of headroom to allow for withdrawal.
• Be within 10
°
of the vertical, forward, aft and athwart ships.
There must also be a viable route for the transducer cable to be routed to the
instrument.
Instrument
ST60+ instruments can be fitted either above or below deck, provided the rear of
the instrument is sited where it is protected from contact with water.
Each instrument must also be positioned where:
• It is easily read by the helmsman.
CAUTION: Keep the rear of the instrument dry
Keep the rear of instrument dry. Failure to observe this caution
could result in damage if water enters the instrument through
the breathing hole or comes into contact with the electrical
connectors.
10˚ maximum
Maximum transducer angle
D4350-1
81262_2.book Page 13 Friday, November 11, 2005 11:11 AM
Содержание ST60+ SPEED INSTRUMENT
Страница 8: ...vi ST60 Depth Instrument Owner s Handbook 81262_2 book Page vi Friday November 11 2005 11 11 AM...
Страница 18: ...6 ST60 Depth Instrument Owner s Handbook 81262_2 book Page 6 Friday November 11 2005 11 11 AM...
Страница 22: ...10 ST60 Depth Instrument Owner s Handbook 81262_2 book Page 10 Friday November 11 2005 11 11 AM...
Страница 38: ...26 ST60 Depth Instrument Owner s Handbook 81262_2 book Page 26 Friday November 11 2005 11 11 AM...
Страница 46: ...34 ST60 Depth Instrument Owner s Handbook 81262_2 book Page 34 Friday November 11 2005 11 11 AM...
Страница 50: ...38 ST60 Depth Instrument Owner s Handbook 81262_2 book Page 38 Friday November 11 2005 11 11 AM...
Страница 52: ...81262_2 book Page 40 Friday November 11 2005 11 11 AM...
Страница 54: ...81262_2 book Page 42 Friday November 11 2005 11 11 AM...