SmartPilot Verado Installation and Commissioning Guide
17
RF GND
POWER IN
SEATALK
Red
Black
or
25 A fuse
20 A circuit
breaker
12 V
Power supply
Type 1 pump
Course computer
Red
Black
Integral
ferrite
Cable length
(pump to course computer)
Cable gauge
(AWG)
(mm
2
)
< 3 m (10 ft)
14
2.5
3 to 5 m (16 ft)
12
4
5 to 7 m (23 ft)
10
6
7 to 10 m (32 ft)
8
10
10 to 16 m (52 ft)
6
16
Note: Power cable and fuse/breaker not supplied.
Select cable gauge according to maximum current rating
of the fuse/breaker and length of cable required.
Connecting power & steering pump
D8550-1