LED indication
LED status and possible solutions
(Green) Wind vane / Gateway updating
• Normal operation — no user action is
required.
(No color) No power
1.
Check the vessel’s battery voltage,
the condition of the battery terminals
and power supply cables, ensuring
connections are secure, clean and free
from corrosion; replace if necessary.
2. Check the power supply cable and
connectors for signs of damage or
corrosion; replace if necessary.
3.
Check that the power cable connector
is fully inserted into the unit and locked
in position.
4.
With the unit turned on, try flexing the
power cable near to the connector to
see if this causes the unit to re-start/lose
power; replace if necessary.
5. With the product under load, using a
multi-meter, check for high voltage drop
across all connectors / fuses etc, and
replace if necessary.