4.4 LED indications — EV-2
LED color
LED code
Status
Action required
Solid green
Normal operation.
• None (normal power up takes <1
minute.)
Long flash green on (x1),
long flash off. Cycle
repeats after 2 seconds.
Unit is initializing; no pilot
or compass functions
currently available.
• None (normal power up takes <1
minute.)
Long flash green on (x2),
long flash off. Cycle
repeats after 8 seconds.
No DeviceNet
connection.
• Ensure network is powered.
• Ensure network cable and
connections are secure and free
from damage.
• If problem persists contact
Raymarine technical support.
Short flash green on
(x7), long flash off. Cycle
repeats after 9 seconds.
DeviceNet connected but
not receiving data.
• If problem persists contact
Raymarine technical support.
Short flash red on (x2),
long flash off. Cycle
repeats after 4 seconds.
No SeaTalk
ng
connection.
• Ensure network is powered.
• Ensure network cable and
connections are secure and free
from damage.
• If problem persists contact
Raymarine technical support.
Short flash red on (x7),
long flash off. Cycle
repeats after 9 seconds.
SeaTalk
ng
connected but
not receiving data.
• If problem persists contact
Raymarine technical support.
Installation