6.5 LED indications
The power LED for this product has a number of flashing (blinking) modes to provide status information for
diagnostics and troubleshooting.
LED color
LED code
Status
User action
Solid
Green
Power On
• None (normal power up takes <1 minute.)
Green 1
blink
Normal
operation
• None
Amber 1
blink
Transducer
disconnected
• Ensure transducer cable and connections are
secure and free from damage.
• Power cycle unit to recover transducer
information.
• If problem persists contact Raymarine technical
support.
Amber 2
blinks
No network
detected
• Ensure network is powered.
• Ensure network cable and connections are
secure and free from damage.
• If problem persists contact Raymarine technical
support.
Amber 5
blinks
Under voltage
(<10.2V)
• Ensure power cable and connections are secure
and free from damage.
• Ensure power supply cabling is consistent with
recommendations.
• If problem persists contact Raymarine technical
support.
Amber 6
blinks
Over voltage
(>34.2V)
• Ensure power supply levels are consistent with
recommendations.
• If problem persists contact Raymarine technical
support.
Red 1
blink
General failure
• If combined with voltage warning, check power
supply and cables.
• Power-cycle the unit.
• If problem persists contact Raymarine technical
support.
Red 3
blinks
Unit
overheating
• Ensure installation environment is within
recommendations.
• Unit will stop pinging and then start again once
normal operating temperature is achieved.
• If problem persists contact Raymarine technical
support.
Red 4
blinks
Problems
with internal
database
• Power-cycle the unit.
• If problem persists contact Raymarine technical
support.
Note:
If any other LED sequence other than described above is seen and persists please contact
Raymarine technical support.
CP100 / CP200