Warning: Transducer cables
Do not remove the transducer cable whilst
the product is powered on, doing so can
cause sparks. If the transducer cable is
accidently removed whilst the product is
powered on, switch the product's power
off, replace the cable and then switch the
power back on.
Caution: Do not cut transducer
cables
• Cutting the transducer cable severely
reduces sonar performance. If the
cable is cut, it must be replaced, it
cannot be repaired.
• Cutting the transducer cable will
void the warranty and invalidate the
European CE mark.
Transducer cable extension
For some installations it may be necessary to extend
the transducer cable.
• Refer
to
Chapter
10
Spares
and
accessories
for
a
list
of
suitable
transducer
extension
cables.
• Raymarine recommends a maximum of one cable
extension for any single transducer cable.
• For best performance, keep all cable lengths to
a minimum.
4.5 Network connection
The unit must be connected to a compatible
Raymarine multifunction display to enable echo
sounder data to be viewed.
Multifunction display connection
Unit connected to a multifunction display using a
RayNet cable.
D12234-3
1
3
2
Note:
The connection panel on your product may
look slightly different to that shown, depending
on variant. The network connection method
remains the same for all products featuring RayNet
connectors.
Item
Description
1
Sonar module.
2
Connector panel for compatible Raymarine
multifunction display.
3
RayNet cable.
Multifunction display configuration (extended
cables)
When the required length of a single network cable
run is greater than 20 m (65.6 ft), a RayNet (male)
to (male) adaptor cable should be used to connect
RayNet cables together .
D12942-1
1
3
3
2
4
Note:
The connection panel on your product may
look slightly different to that shown, depending
on variant. The network connection method
remains the same for all products featuring RayNet
connectors.
Item
Description
1
Sonar module.
2
Connector panel for compatible Raymarine
multifunction display.
3
RayNet cables.
4
RayNet (Male) to (Male) adaptor cable.